Grate combustion 390 to 1250 kw, fully automatic wood boiler, for the combustion of woodchips, pellets, shavings and mixed wood
Table of Contents

Advertisement

Design information
34,54 mm37,56 mm
< 200
A Axis, agitator
B Screw axis
Sizing the horizontal discharge AH with agitator and discharge screw
a
b
c
d
e
f
g
6
48
(cont.)
42,99 mm
a
18,03 mm
ø 1490
D
C
d
> 10000
4,33 mm
410
14,59 mm
c
b
7,29 mm
585
C Rotational direction
D Centre, agitator
Min. length of protective panel for bunker walls
Open conveyor channel downstream of agitator centre
Open conveyor channel upstream of agitator centre max. 2.8 m
Discharge circuit from 3.9 to 6.1 m depending on bunker situation
Depending on: fuel, installation position, compression, etc.
A
B
Sealed channel
Wall clearance to centre
Effective scope 0.8 to 0.95 x f