Slot Discharge, For Pulling - Viessmann KOB PYROTEC Technical Manual

Grate combustion 390 to 1250 kw, fully automatic wood boiler, for the combustion of woodchips, pellets, shavings and mixed wood
Table of Contents

Advertisement

Design information
FZD Maximum pressure force on the weld base for the pushrod
drive
FZZ Maximum tensile force on the weld base for the pushrod drive
Number of pushrods
FS
FR
Standard version
AS-001/2
Heavy version
Y article

Slot discharge, for pulling

The drawing below is a general arrangement and should not be used
for construction design. A project-related drawing must be produced
for construction design.
Specification
Slot discharge, for pulling
a
b
c
d
e
f
6
54
(cont.)
mm
mm
FS1
FR1
160 kN
130 kN
240 kN
195 kN
mm
mm
mm
For max. dumping height, see page 52
mm
mm
1
1x FS1
1x FR1
FZZ
FZD
FG1
362 kN
484 kN
12 kN
542 kN
722 kN
15 kN
Note
Only KÖB original weld bases are permissible for the pushrod drive.
Screw
D = 190 mm
650
380
350
For max. dumping height, see page 52
> 3200
1500-2500
2
3
1x FS1
2x FS1
1x FR1
110
FM1
Z
100 kN
125 mm
150 kN
150 mm
Screw
D = 250 mm
700
430
400
> 3200
1500-2500
PYROTEC

Advertisement

Table of Contents
loading