AMX DXLink Instruction Manual page 113

Dxlink twisted pair transmitters/receiver dxlink multi-format wallplate transmitter dxlink multi-format decor style wallplate transmitter (us) dxlink multi-format transmitter module dxlink hdmi transmitter module dxlink hdmi receiver module
Hide thumbs Also See for DXLink:
Table of Contents

Advertisement

3.
No Master on the network:
a. Use your PC to set up a Virtual NetLinx Master (see page 121) in NetLinx Studio (leave
NetLinx Studio open to the OnLine Tree when done).
b. Apply power to module and set it to Static IP Mode.* The default static IP address is
192.168.1.2. (Note that when module is in Static IP Mode, the Link/Act LED will be OFF and
the Status LED will be ON.)
Master on the network:
a. Launch NetLinx Studio and open the OnLine Tree.
b. Apply power to module and set it to DHCP Mode.*
4.
On the bottom of module, set the DIP switch's #1 and #3 Toggles to ON. (Remember to set the
#1 and #3 Toggles back to OFF when the file transfer is complete if the module does not require
network connectivity.)
5.
Connect an RJ-45 cable from the ICS LAN 10/100 port on the Transmitter or Receiver Module to
the PC running NetLinx Studio.
6.
No Master on the network
Master):
Note: The DXLink Module is present on the network but does not display until the following steps
are completed and the workspace is refreshed.
a. From the Tools menu, select Telnet Session to open the Telnet Settings window.
b. Click New and enter the TCP/IP Address for module (192.168.1.2). Click OK.
c. Select the module's address in the List of Addresses and click OK.
d. At the prompt ( > ), enter SET CONNECTION .
e. Enter " T " for TCP/URL.
f. Enter the (Virtual NetLinx) Master IP/URL (192.168.1.100).
Use the defaults for the remaining parameters (press Enter to move from default to default).
Master on the network:
7.
Right-click in the workspace and select Refresh System OnLine Tree. The module will appear in the
OnLine Tree and locate the DXLink Module and the virtual device ID assigned to it (32002 in the
example). For the Device Number location, see FIG. 40 on page 105.
The module is ready for the KIT file transfer.
* Press and hold the ID Pushbutton for at least 10 seconds. The NetLinx LEDs toggle back and forth
during this time and then blink faster in unison. Release on the faster blink. When the Pushbutton is
released, the module toggles from either static to dynamic IP addressing or vice versa and remains in that
mode until the ID Pushbutton is used to reset it. The module automatically reboots to complete the
process.
Instruction Manual – DXLink™ Twisted Pair Transmitters/Receiver
(set a TCP connection from the DXLink Module to the Virtual NetLinx
Go to Step 7.