Section 9, Transaction Language 1 (TL1)
TL1 Error Codes
Table 9-6. TL1 Editing Data Dictionary for STS-1 (Continued)
Keyword
STS1CFGSEC
EXTCLK
STS1CVTHRS
STS1MAXNUMSW
STS1MINSWPERIOD
STS1PROT
SYSCARDCOMMRLY
SYSCARDRLY
TMG
9-20
Type
Domain
ENUM
One of the following:
• DISABLED
• EXTB
ENUM
One of the following:
• Disable
• 1E3
• 1E4
• 1E5
• 1E6
INT
0, 1, 2, ..., N
INT
0, 1, 2, ..., N
Y/N
Y or [N]
Y/N
Y or [N]
Y/N
Y or [N]
ENUM
One of the following:
• LPD
• INT
• EXTNONREV
• EXTREV
MX2800 STS-1 User Manual
Description
Provision secondary clock reference (Disabled
or External B)
Indicates a limit on the number of code viola-
tions accepted by the unit over the DS3 before
the unit switches controller cards
• 1E3 - 1 out of every 1,000 bits contains a CV
• 1E4 - 1 out of every 10,000 bits contains a
CV
• 1E5 - 1 out of every 100,000 bits contains a
CV
• 1E6 - 1 out of every 1,000,000 bits
contains a CV
Maximum number of times per hour the unit is
allowed to switch between controller cards (if
number is exceeded, the unit will issue a trap)
Number of seconds that must pass after a
protection switch before another protection
switch will be allowed
Identifies status of system network protection
• Yes (Y) - enables system network protection
• No (N) - disables system network protection
Identifies status of System Communication Fail
alarm relay
• Yes (Y) - enables alarm relay response
• No (N) - disables alarm relay response
Identifies status of System Controller Card
alarm relay
• Yes (Y) - enables alarm relay response
• No (N) - disables alarm relay response
Identifies timing supply for the DS3
• Loop timing
• Internal (free-run) timing
• External non-revertive
• External revertive
61204659L1-1A