Section 9, Transaction Language 1 (TL1)
TL1 Error Codes
EQPT Data Dictionary
Table 9-9
contains entries that are used to edit or retrieve options for the equipment portion of the
MX2800. When performing TL1 edit commands from this table, the value of rr should be EQPT, and the
<aid> value should be the following:
401 - Generic
Keyword
CLOCKSTATUSRLY
CLOCKPRIRLY
CLOCKSECRLY
CLOCKLOARLY
DIAGBERCLEARCOUNT
DIAGBERTCOUNT
DIAGBERTSYNC
9-26
Table 9-9. TL1 Editing Data Dictionary for EQPT
Type
Domain
Y/N
Y or [N]
Y/N
Y or [N]
Y/N
Y or [N]
Y/N
Y or [N]
Y/N
Y or [N]
INT
0, 1, 2, ..., N
ENUM
One of the following:
• NOSYNC
• SYNC
MX2800 STS-1 User Manual
Description
Provisions alarm relay response for the
Clock Status Changed alarm
• Yes (Y) - enables alarm relay response
• No (N) - disables alarm relay response
Provisions alarm relay response for the
Primary Reference Failure alarm
• Yes (Y) - enables alarm relay response
• No (N) - disables alarm relay response
Provisions alarm relay response for the
Secondary Reference Failure alarm
• Yes (Y) - enables alarm relay response
• No (N) - disables alarm relay response
Provisions alarm relay response for the
Clock Loss of Activity alarm
• Yes (Y) - enables alarm relay response
• No (N) - disables alarm relay response
Clears BERT count
• Yes (Y) - clears the BERT count
• No (N) - does not clear the BERT count
Error count
Identifies state of Pattern Synchronization
• NOSYNC - there is no pattern sync
• SYNC - pattern sync is available
61204659L1-1A