WI817C 08/00
FUNCTION MODE/DEALER PROGRAM MODE
The keypad can provide a wide assortment of utility functions as summarized in the Keypad Programming Modes. The
functions are displayed in a prompting "YES/NO" format. To skip a function, answer NO (press the
and execute a function, answer YES (press the
here in its normal displayed sequence. However, since not all functions are designed for all systems (or intended for all
users), only functions that are applicable and active are displayed. (For example, if no zones are bypassed, "DISPLAY ZN
BYPASSED" will not appear.) Furthermore, functions that are intended for use by the installer or servicer will not be
displayed. Note: Functions may be manually scrolled forward or backward using the
respectively.
To return to normal keypad operation, press the
operating mode if no activity is detected for longer than one minute.)
Note: (1) In all UL-listed applications and in high-security installations, only those users having valid codes can access
the Function Mode. (2) Due to space constraints, GEM-RP2ASe2 message displays are abbreviated.
Remember: (1) Functions that are not active, not programmed and/or not applicable to the user's authority level will be
suppressed and will not display. (2) Press NO (
(3) The GEM-RP2ASe2 displays abbreviated messages that auto scroll.
DISPLAY ZN FAULTS
Press YES (
button) to identify all unsecured zones (within the keypad's area) while disarmed. Press NEXT
E
(
button) to scroll through the zones. (Zones may be bypassed in this mode by pressing the
E
Manually bypassed zones will be indicated when displaying status.
DISPLAY ZN BYPASSED
Press YES (
button) to display zones that have been deactivated. Press NEXT (
E
the zones.
DISPLAY ZN DIRECTORY
Press YES (
button) to display a list of all programmed zone descriptions in the keypad area. Press NEXT (
E
button) to scroll through the zones. To return to the system, press the
ACTIVATE BELL TEST
Press YES (
button) to activate the burg relay output (while disarmed) for about 2 seconds. If the device does not
E
sound, it may be defective.
DISPLAY PHONE #'S
The panel can function as an auto dialer to any of four programmed telephone numbers. (Telephone numbers must be
programmed through Napco PCD3000 Quickloader software.) Select Telephone #1-4 using NEXT (
(
) buttons, then press the
F
appear to be disconnected while dialing but will return to normal after a few seconds.)
DISPLAY SYS TRBL
Press YES (
button) to check trouble (LOW BATTERY, AC POWER LOSS, etc.). Wait for the display to scroll
E
through multiple system troubles, or use the NEXT (
DISPLAY FIRE ALARM
To display Fire Zone(s) in alarm, access DISPLAY FIRE ALARM and scroll through the zones using the NEXT (
button). Correct the problem, then press the
L
NAPCO Security Systems
button or the
E
E
button) to skip a function; press YES (
F
J
button. Pick up the phone to initiate dialing of the displayed number. (The phone will
) and PRIOR (
E
button to restore the "SYSTEM READY" condition.
C
J
button). The complete function list is provided
button. (The keypad will automatically return to its normal
button at any time.
C
) buttons to manually scroll.
F
X
GEM-P3200 Installation Instructions
Page 25
button); to select
F
and the
buttons,
A
B
button) to execute it.
E
button).
B
button) to scroll through
E
) and PRIOR
E
!
E
E