NAPCO Gemini GEM-P3200 Installation Instructions Manual page 20

Control panel/communicator
Hide thumbs Also See for Gemini GEM-P3200:
Table of Contents

Advertisement

!
Page 20
Configuring the GEM-RP2ASe2 and GEM-RP3DGTL Keypad
Up to 7 GEM-RP2ASe2 and/or GEM-RP3DGTL keypads may be connected to the panel (Keypads 1–7). Each must be
configured for a keypad address. In addition, the keypad may be configured to disable (a) touchpad backlight; (b) LCD
backlight; and (c) entry sounder. Keypads are configured by the proper selection of jumpers. Refer to the label on the
circuit board inulation paper for jumper locations and a summary of settings.
KEYPAD NUMBER
KEYPAD
NUMBER
1
2
3
1
OFF or
OFF
OFF
ON*
2
OFF
ON
OFF
3
ON
ON
OFF
4
OFF
OFF
OFF
5
ON
OFF
ON
6
OFF
ON
ON
ON
ON
ON
7
TOUCHPAD BACK LIGHT
Cut Jumper A to disable touch pad backlighting to conserve 11mA standby current.
LCD BACKLIGHT
Cut Jumper B to disable LCD backlighting.
DISABLE SOUNDER
Cut Jumper C to disable the sounder. (Do not disable in UL applications.)
X
GEM-P3200 Installation Instructions
KEYPAD ADDRESS
If more than one keypad is installed:
!
Each must be assigned a unique address (that is, no two keypads may be
PARK
numbered alike).
!
Keypads must be addressed consecutively (that is, missing numbers are not
permitted).
!
Only Keypad No. 1 may be used for programming. (However, for ease of
STORE SPARE
programming, it is recommended that a GEM-RP1CAe2 be selected as Keypad
JUMPER AT THIS
#1.)
POSITION
Assign the keypad address number by selecting Jumpers J1–3 in
accordance with the table at left.
*Note: (1) Keypads are factory supplied with no jumpers installed and a as
such are automatically configured as Keypad No. 1. (2) Only one keypad
in the system may be configured as Keypad No. 1, otherwise none will
function.
NAPCO Security Systems, Inc.
333 Bayview Avenue, Amityville, New York 11701
For Sales and Repairs, call toll free: (800) 645-9445
For direct line to Technical Service, call toll free: (800) 645-9440
Internet: http://www.napcosecurity.com
WI817C 08/00
L
NAPCO Security Systems

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents