Appendix D
24
Change SW4: Software dip switch #4. An EEPROM command.
Below is the ^AB sequence.
12345678
^ABxxxxxxxx
*******.))
******.)))
*****.))))
****.)))))
***.))))))
**.)))))))
*.))))))))
.)))))))))
29
Printer Statistics:
0
Print statistics to serial port
1
Print statistics on a label
2
Clear the printed labels variable in the statistics
3
Clear the printed inches variable in the statistics
30
Change Clock: Use the sequence below to set the time and date of the
optional real-time clock:
^D30 (return)
HH:MM:SS (return)
DD/MM/YY/W (return)
31
Show Clock: This command will send the date and time to the serial port.
32
Reset Machine: Restores printer to power-up settings. Also used to set the
EEPROM fields in memory. Section 5.3.
33
Display Model and Revision Number.
35
Contrast Window Adjust:
1
60% of Base
2
70% of Base
3
80% of Base
4
90% of Base
5
Base (default)
6
110% of Base
7
120% of Base
8
130% of Base
9
140% of Base
XX
36
Adjust Contrast Base: An EEPROM command. The ^AXX is between 10 and
200%. Section 5.3.
400 Operators Manual
Always 0
Always 0
Always 0
Always 0
1=Auto-size on Power-up, 0=Disable
1=Blow-hole Sensing Enable, 0=Disable
Always 0
Always 0
Quick Reference Command Summary