Printer Commands
5.3.1

SOFTWARE DIP SWITCHES AND EEPROM COMMANDS

The following commands are different from the other printer commands in that they are stored in
EEPROM, are non-volatile and configure the machine upon power-up. Once sent to the printer,
they do not need to be sent again.
The printer will only configure to the following commands after a the machine has been powered
off and then turned back on. The printer will not accept these commands until this is done.
^A
^D
COMMAND
20
Change baud rate: Unless otherwise requested by the customer, the baud rate of
a 400 printer, out of the box, is 9600. (i.e. to change baud to 19200 use ^A8^D205)
0
110 Baud
1
150 Baud
2
300 Baud
3
600 Baud
4
1200 Baud
5
2400 Baud
6
4800 Baud
7
9600 Baud
8
19200 Baud