Computer Link Function - Sharp JW-20FL5 User Manual

Fl-net module (board)
Table of Contents

Advertisement

Chapter 9: Message transfers

9-5 Computer link function

(Compatible with Satellite net: SHARP's proprietary message format)
The computer link function is SHARP's proprietary transmission message format (request TCD1000,
response TCD12000, and can be used between PCs equipped with a SHARP FL-net module (board).
1 Specify the node number, command details, and transaction code to communicate from this
node.
2 The message (command) is received, the messages are processed and a response is returned.
The command contains three types: read, write, and control commands.
Type
Read command
9
Write command
Control command
1 Send (request)
2 Receive (response)
FL-net
This
node
Function
Monitor relay
Monitor timer/counter current value
Monitor the register
Read program memory
Read system memory
Read date
Read time
Set/reset relay
Set/reset timer or counter
Write to register
Write same data to register
Write program
Write to system memory
Set date
Set time
Monitor PC operation status
PC stop/release stop operation
Set write enable mode
Monitor write enable mode
9-16
Target
node

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jw-20fltJw-50flZ-336j

Table of Contents