Sharp JW-20FL5 User Manual page 31

Fl-net module (board)
Table of Contents

Advertisement

Chapter 6: Connection/Wiring
Wiring the power source
When a 10BASE5 is used, 12 VDC power should be supplied to the transceiver.
Supply power to the 12 VDC power supply input terminal of the Z-336J using a commercial constant
voltage power supply unit.
Z-336J
6
* Use a fuse that will melt with
time lag
Remarks
- Use a power supply that is dedicated for use by the Z-336J.
- Do not reverse the positive and negative connections to the power terminals. Reversing the polarity
may damage the Z-336J.
Twisted pair wires
Red wire (+)
Black wire (-)
* Fuse (0.6 A)
12 VDC
Item
Supply voltage
Current capacity
12 VDC power supply input terminal
Green wire
Cable
(ground)
(Accessory: Connector,
cable length 1.5 m)
Case
6-6
Specifications
12 VDC –5%
0.5 A minimum.