Set time (COM = B3
(H)
[Format]
Ë Command
COM
H
M
Ë Response
COM
ACK
COM
=B3
(H)
H
= Hour
M
= Minute
S
= Second
CTRL
= Control data
[Function]
- Write time data
[Execution condition]
- Write enable mode
- PC operation status
[Example]
- Set time data to 18 o'clock, 10 minutes, and 20 seconds.
Ë Command
B3
18
10
18 o'clock 10 minutes 20 seconds Run clock
Ë Response
B3
00
)
S
CTRL
(00
to 23
: BCD)
(H)
(H)
(00
to 59
: BCD)
(H)
(H)
(00
to 59
: BCD)
(H)
(H)
00
: Run clock
(H)
01
: Stop clock
(H)
: Mode 1 and mode 2
: Stopping, operating