Fl-net module (board)
Table of Contents

Advertisement

Assemble the coaxial cable connector
Note: The gap between the center pin and the insulator should not be larger than 1 mm. The insula-
tion material must be intact.
(5) Transceiver
Installing and securing a tap type transceiver
The method and location for installing a transceiver depends on the local conditions. However,
common installation locations are as follows.
Install on a wall
Install in the free access space under the floor
Install in the ceiling or in a cable rack
Install near a station
The precautions when installing a transceiver are as follows:
Secure the transceiver on the floor or a flat surface using foot, or secure it using self-tapping
screws.
When installing a transceiver in the ceiling or below the floor, select a location that is easy to
access for maintenance and checking.
The installation distance between transceivers is 2.5 m. (Use the markers on the cable that are
spaced every 2.5 m)