Press the Enter key at the ROMPaq welcome screen. A screen displays the devices in your server that
2.
can be upgraded.
Use the cursors to select iLO Management and press the Enter key. A screen displays the firmware
3.
images that ROMPaq can install.
Use the cursors to highlight the appropriate image and press the Enter key.
4.
Press the Enter key again. ROMPaq reads the firmware image. If you are prompted to enter
5.
additional diskettes put in the appropriate diskette and press the Enter key.
Press the Enter key again to begin reprogramming the ROM. Do not power cycle, reboot, or turn off
6.
the system while this process is taking place.
After you receive a message that the flash programming has completed successfully, press the Enter
7.
key.
Press the Enter key to reprogram another device, or press the Esc key to return to the A:\ prompt.
8.
It might be necessary to set the Security Override Switch to perform the ROMPaq upgrade. The ROMPaq
program informs you if the Security Override Switch must be set.
If none of the above solves the issue:
Remove the power from the server and the system battery.
1.
Wait a few minutes.
2.
Replace the battery, and power to the server.
3.
This may return iLO to the default state.

Enclosure bay static IP changes do not take effect

For a blade to automatically use enclosure bay static IP, the following must be true:
The enclosure bay static IP record must contain a valid IP range.
1.
The enclosure bay static IP record must have the respective bay identified as a bay to participate in
2.
enclosure bay static IP.
The enclosure bay static IP record will not have a valid IP range for new enclosures. Plugging your servers
into this enclosure before setting up the enclosure bay static IP record forces all blades to use the default
setting of DHCP. If this happens and you want to use enclosure bay static IP, you must first set up the
enclosure bay static IP record on the first blade. After you have set up the enclosure bay static IP record,
log in to each of the other blades and modify the network settings to use enclosure bay static IP. You can
use either the interface or an XML script. The easiest way to set up each blade is use the front crash cart
to log into each blade and make the network modifications.
To use enclosure bay static IP to manage iLO networking:
Plug one blade into the first slot of the enclosure leaving the rest of the enclosure empty.
1.
Log in to this blade through the front crash cart. The default IP address is 192.168.1.1.
2.
Set up the enclosure bay static IP using the blade setup wizard or by canceling the wizard and
3.
browsing to the enclosure bay static IP set up tab.
Save the settings.
4.
After the settings are saved, other blades can be inserted into the enclosure.
Do not insert other blades into the enclosure until the enclosure bay static IP record has been saved. After
the other blades are inserted, iLO initializes its network to the address specified in the enclosure bay static
IP record, assuming one of the following: