Proxy Server Issues; Troubleshooting Alert And Trap Problems; Inability To Receive Insight Manager 7 Or Systems Insight Manager Alarms (Snmp Traps) From Ilo; Ilo Security Override Switch - HP Integrated Lights-Out User Manual

Integrated lights-out firmware 1.91
Hide thumbs Also See for Integrated Lights-Out:
Table of Contents

Advertisement

Proxy server issues

If the Web browser software is configured to use a proxy server, it will not connect to the iLO IP address.
To resolve this issue, configure the browser not to use the proxy server for the IP address of iLO. For
example, in Internet Explorer, select Tools>Internet Options>Connections>LAN Settings>Advanced, and
then enter the iLO IP address or DNS name in the Exceptions field.

Troubleshooting alert and trap problems

Alert
Test Trap
Server Power Outage
Server Reset
Failed Login Attempt
General Error
Logs
Security Override Switch
Changed: On/Off
Rack Server Power On
Failed
Rack Server Power On
Manual Override
Rack Name Changed
Inability to receive Insight Manager 7 or Systems Insight
Manager alarms (SNMP traps) from iLO
A user with the Configure iLO Settings privilege must connect to iLO to configure SNMP trap parameters.
When connected to iLO, be sure that the correct alert types and trap destinations are enabled in the
SNMP/Insight Manager Settings screen of the iLO console application.

iLO Security Override switch

The iLO Security Override switch allows emergency access to the administrator with physical control over
the server system board. Setting the iLO Security Override switch allows login access, with all privileges,
without a user ID and password.
The iLO Security Override switch is located inside the server and cannot be accessed without opening the
server enclosure. To set the iLO Security Override switch, the server must be powered off and
disconnected from the power source. Set the switch and then power on the server. Reverse the procedure
to clear the iLO Security Override switch.
A warning message is displayed on the iLO Web pages, indicating that the iLO Security Override switch
is currently in use. An iLO log entry is added recording the use of the iLO Security Override switch. An
SNMP alert may also be sent upon setting or clearing the iLO Security Override switch.
Explanation
This trap is generated by a user through the Web configuration page.
Server has lost power.
Server has been reset.
Remote user login attempt failed.
This is an error condition that is not predefined by the hard-coded MIB.
Circular log has been overrun.
The state of the Security Override Switch has changed (On/Off).
The server was unable to power on because the BL p-Class rack
indicated that insufficient power was available to power on the server.
The server was manually forced by the customer to power on despite the
BL p-Class reporting insufficient power.
The name of the ProLiant BL p-Class rack was changed.
Troubleshooting iLO 171

Advertisement

Table of Contents
loading

Table of Contents