Run Codes - Genie GCL-MT Installation Manual

Medium duty operator trolley
Hide thumbs Also See for GCL-MT:
Table of Contents

Advertisement

Error Codes
(cont')
To view the error code memory: (Fig. 1 & 2)
1) Press CAL/RUN to enter calibration mode.
2) Press SCROLL (
) or (
>
"ERROR CODE 1 ."
The display will begin flashing the error code number and
2-digit error code followed by its description.
Reminder: Error code number 1 is the latest code generated.
3) Press SET/CLEAR. The display will now read "ERROR CODE 2 > ."
(This is the error code which was generated before error code 1.)
4) Repeat step 3 until all 10 error codes have been displayed or
move on to step 5 when ready.
5) Press CAL/RUN to return to run mode.
NOTE: For all error codes see Appendix C, Sections 10.7 - 10.8.

Run Codes

The operators also include a run code memory that stores the last 10 run
events. These codes are stored with or without power. Each time the
operator runs or stops, it generates a code that it stores in this memory
(Why the operator ran or stopped). Used together with the error code
memory, it becomes a powerful troubleshooting aid.
The run code memory stores the last 10 error codes in sequence. Once 10
codes are stored, the oldest code is erased to make room for the newest
code. These codes are displayed in calibration mode.The display will flash
the number of the run code and the 2-digit run code followed by a
description of the run code. Fig. 3 & 4.
GCL-MT
Medium Duty Operator
) until display reads
www.geniecompany.com
RUN CODE 1 3C
Figure 3
HALT DOWN LIMIT
Figure 4
08-12