Genie GCL-MT Installation Manual page 37

Medium duty operator trolley
Hide thumbs Also See for GCL-MT:
Table of Contents

Advertisement

Run Codes
(cont')
To view the run code memory: (Fig. 3 & 4)
1) Press CAL/RUN to enter calibration mode.
2) Press SCROLL (
) or (
The display will begin flashing the run code number and code
followed by its description.
Remember: run code number 1 is the latest code generated.
3) Press SET/CLEAR. The display will now read "RUN CODE 2 > ."
(This is the run code which was generated before run code 1 )
4) Repeat step 3 until all 10 run codes have been displayed or
move on to step 5 when ready.
5) Press CAL/RUN to return to run mode.
NOTE:
For all run codes see Appendix C, Section 10.6.
TROUBLESHOOTING EXAMPLE USING RUN AND ERROR CODE
Fig. 5
MEMORIES.
.
1. In Calibration Mode, display and write down each Run Code
and Error Code stored in memory.
2. List as shown below.
3. Refer to Appendix C to interpret the codes.
In this example, the operator was opened using the OPEN key on
the keypad and stopped at the up limit. The OPEN wall button
was then activated, causing the "6D" code to be generated since
the operator could not open when it is already at the up limit.
The CLOSE wall button was then activated, causing the operator
to close. While closing, the Normally-Open (N-O) Safety Input
was activated, causing the operator to stop and then reverse,
stopping at the up limit.
GCL-MT
Medium Duty Operator
) until display reads "RUN CODE 1 > ."
www.geniecompany.com
ERROR
CODES
NUMBER
CODE
1
45
REVERSED DUE TO ACTIVE
N-O SAFETY INPUT
2
6D
WOULD NOT OPEN —
ALREADY AT UP LIMIT
00
3
4
00
5
00
6
00
7
00
GCL-MT STORES "00" CODES IN UNUSED RUN AND ERROR
CODE MEMORY LOCATIONS FROM THE FACTORY.
AS ERROR OR RUN CODES ARE
8
00
RECORDED, THE "00" CODES ARE REPLACED WITH VALID CODES
9
00
10
00
00
Figure 5
STOPPED AT UP LIMIT
STOPPED DUE TO ACTIVE
N-O SAFETY INPUT
CLOSED FROM
CLOSE WALL BUTTON
STOPPED AT UP LIMIT
OPENED FROM
OPEN KEY ACTIVATION
08-12
RUN
CODES
CODE
NUMBER
1
3D
2
35
20
3
4
3D
14
5
6
00
7
00
00
8
9
00
10
00
8.3

Advertisement