Screw Terminal Assignments

INPUT
OPEN
11-POSITION
TERMINAL BLOCK
CLOSE
INSIDE ELECTRIC BOX
STOP
GND
1-BTN
ODC STB
ODC STB
N-O REVERSE
N-O REVERSE
EXT INTLK
EXT INTLK
2-POSITION TERMINAL
L1 / L1
BLOCK
(INSIDE ELECTRIC BOX)
N / L2
Other Connections
PWR
RADIO AND
RAD
ACCESSORIES
(Radio Input Control)
PIGTAIL
GND
EXPANSION PORT
PLUG CONNECTIONS
INSIDE ELECTRIC BOX
TRANSFORMER
BRAKE
MOTOR
HOIST INTLK
LIMIT SENSOR
GCL-MT
Medium Duty Operator
Section 10: Appendix B
FUNCTION
Causes door to open if not at Up Limit. Causes a closing door to reverse.
Causes door to close if not at Down Limit.
Causes a moving door to stop. Prevents the operator from running.
Common ground connection for Open, Close, Stop & 1-Btn Inputs.
Causes door to open if not at Up Limit or Mid-Stop Limit.
Causes door to close if at Up Limit or Mid-Stop Limit.
Causes door to stop if opening. Causes a closing door to reverse.
Reverses a closing door if photocell beam is blocked.
NOTE: STB's must be enabled in Calibration Mode.
Reverses a closing door if photocell beam is blocked.
NOTE: STB's must be enabled in Calibration Mode.
Causes a closing door to reverse. NOTE: Will not open a stopped door.
Causes a closing door to reverse. NOTE: Will not open a stopped door.
Causes a moving door to stop.
Prevents the operator from running when contact is open.
Operates even if microcontroller is non-functional.
Causes a moving door to stop.
Prevents the operator from running when contact is open.
Operates even if microcontroller is non-functional.
Power to operator.
Power to operator.
Power for radio & other accessories. +20 to +40VDC, fused at 250mA (F1). Connect to radio or other accessory's power input.
Causes door to open if not at Up Limit or Mid-Stop Limit.
Causes door to close if at Up Limit or Mid-Stop Limit.
Causes a closing door to reverse.
Common ground connection for PWR and RAD terminals.
Connects accessory modules to operator.
Connects main transformer to control board.
Connects brake solenoid to control board.
Connects motor and capacitor to control board.
Causes moving door to stop. Prevents the operator from running.
Operates even if microcontroller is non-functional.
Causes door to stop at top and bottom of normal travel.
Normally-Open Dry Contact to GND.
Normally-Open Dry Contact to GND.
Normally-Closed Dry Contact to GND.
Normally-Open Dry Contact to GND.
ODC Series II Safe-T-Beams® ONLY to these inputs. (not polarity sensitive)
ODC Series II Safe-T-Beams® ONLY to these inputs.
Normally-Open 2-Wire Non-Monitored Edge Sensor.
Normally-Open 2-Wire Non-Monitored Edge Sensor.
Normally-Closed dry contacts.
(board will energize these contacts at nominal +24VDC).
Normally-Closed dry contacts.
(board will energize these contacts at nominal +24VDC).
120VAC: Connect to Line (Hot) / 240VAC: Connect to Line 1.
120VAC: Connect to Neutral / 240VAC: Connect to Line 2.
Connect to radio or other accessory's signal (output).
Connect to radio or other accessory's ground input.
Accessory Module Ribbon Cable.
Transformer Plug.
Brake Solenoid Plug.
Motor Plug.
Hoist Interlock Plug or Jumper.
Limit Sensor Plug.