Run Codes - Genie GCL-GH Installation Manual

Heavy duty operator hoist
Hide thumbs Also See for GCL-GH:
Table of Contents

Advertisement

Error Codes
(continued)
To view the error code memory:
L
1) Press CAL/RUN
to enter calibration mode.
CAL
C
RUN
R
until display reads "ERROR CODE 1 > ".
2) Press SCROLL
SCROLL
The display will begin flashing the error code number and 2-digit
error code followed by its description.
Reminder: Error code number 1 is the latest code generated.
. The display will now read "ERROR CODE 2 > ."
SET
3) Press SET/CLEAR
CLEAR
(This is the error code which was generated before error code 1.)
4) Repeat step 3 until all 10 error codes have been displayed or move on to
step 5 when ready.
5) Press CAL/RUN
CAL
to return to run mode.
RUN
NOTE: For all error codes see Appendix C, Sections 10.11 - 10.12.

Run Codes

The operators also include a run code memory that stores the last 10 run events.
These codes are stored with or without power. Each time the operator runs or stops, it
generates a code that it stores in this memory (Why the operator ran or stopped). Used
together with the error code memory, it becomes a powerful troubleshooting aid.
The run code memory stores the last 10 codes in sequence. Once 10 codes are stored,
the oldest code is erased to make room for the newest code. These codes are displayed
in calibration mode. The display will flash the number of the run code and the 2-digit
run code followed by a description of the run code. Fig. 3 & 4.
GCL-GH
Heavy Duty Operator
www.geniecompany.com
OPEN
RUN CODE 1 3C
CLOSE
STOP
CAL
SET
SCROLL
RUN
CLEAR
SCROLL
Figure 3
OPEN
HALT DOWN LIMIT
CLOSE
STOP
CAL
SET
SCROLL
RUN
CLEAR
SCROLL
Figure 4
03-12