TECHNICAL TROUBLESHOOTING

Master Power (ON / OFF) Switch turned ON - Power light or indicator is not lit

Low Internal Product Temperatures

Page 36
Control power cord(s) unplugged
NO
Line voltage not present
NO
Check for Line
voltage at terminal
block terminals
(#1 & #6) and
(#2 & #6)
NO
High
Limit Tripped
Carbon Build up
on Platen or Grill
surface
NO
Low product quality
(before cooking)
NO
Grill is out of
calibration
NO
System gap out of
calibration
NO
Cook time too short
Reconnect power supply,
YES
Check Ansul reset
Circuit breaker at
service panel is
YES
"OFF" or tripped
Reset circuit breaker
Replace power switch
YES
Remove platen cover
YES
and check high
limit...Check cause!
Scrape grill surface
and / or squeegee
YES
upper platen
Use product that
YES
meets quality
standards
Recalibrate grill
YES
controller per
instructions
Properly recalibrate
YES
system gap
YES
Increase cook time
Part # JIBSM08 Rev 7 (08/04/09)