Checking The Firmware Configuration; Downloading The Error Log Information; Error Conditions - Fujitsu SPARC Enterprise M8000 Service Manual

Oracle
Hide thumbs Also See for SPARC Enterprise M8000:
Table of Contents

Advertisement

2.5.2.2

Checking the Firmware Configuration

Login authority is required to check the firmware configuration. The following procedure for
these checks can be made from the maintenance terminal:.
1. Log in to the XSCF.
2. Execute the version command.
XSCF> version
The version command will print the firmware version information to the screen. For
the detailed procedure, see the SPARC Enterprise M3000/M4000/M5000/M8000/M9000
Servers XSCF User's Guide.
2.5.3

Downloading the Error Log Information

If you want to download the error log information, use the XSCF log fetch function. The
XSCF Unit has an interface with external units so that a service engineer can easily obtain
useful maintenance information such as error logs
Connect the maintenance terminal, and use the CLI or BUI to issue a download instruction to
the maintenance terminal to download Error Log information over the XSCF-LAN.
Note – When the XSCF unit has a redundant configuration, log in also to the standby XSCF
and obtain the log file in the same manner.
2.6

Error Conditions

This section describes error conditions and relevant corrective actions.
This work is explained in the following sections:
Section 2.6.1, "Predictive Self-Healing Tools" on page 2-27
Section 2.6.2, "Monitoring Output" on page 2-28
Section 2.6.3, "Messaging Output" on page 2-30
Details of the fault information, see the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF User's Guide.
See the Oracle Solaris 10 documentation for more information on predictive self-healing.
2-26
SPARC Enterprise M8000/M9000 Servers Service Manual • October 2012

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc enterprise m9000

Table of Contents