9. Based on
operation of IOUA.
10. Switch on all main line switches for the AC section (ACS) in the power supply
system.
11. Confirm that the XSCF STANDBY LED (green) on the operator panel remains lit.
If it is blinking, wait until it remains lit.
12. Use one of the following methods to start (power on) all domains at once.
Press and hold down (for less than four seconds) the POWER switch on the operator
panel.
From the console that is connected to XSCF, execute the poweron -a.
Power to all the domains is turned on. Firmware version synchronization of the target
domain is automatically performed.
For details of the power-on operation, see
page
User's Guide.
13. Log in to XSCF.
14. Confirm that the mounted IOUA has been recognized by the server, and the error
indicator asterisk (*) is not displayed.
XSCF> showhardconf -M
25-22
SPARC Enterprise M8000/M9000 Servers Service Manual • October 2012
Section 13.4, "Cold Replacement" on page
4-22, and the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF
13-21, perform the mounting
Section 4.4.2, "Powering the Server On" on