The power to all the domains is turned on, and then the power-on self test (POST) is
executed. When ok prompt displayed on the console of relevant domain, POST is
completed.
For details of the power-on operation, see
page
User's Guide.
14. Confirm that the replacement components are normal by using the showhardconf
or showstatus command of XSCF.
Unless "*" is displayed for the replacement RDPF, it is operating normally.
For details of the showhardconf command and showstatus command, see the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User's Guide, the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference
Manual, or the man page.
Note – The showstatus command displays information on degraded components.
15. Restore the original mode switch setting on the operator panel.
Note – When the maintenance work is completed, be sure to confirm the mode switch
setting and return the switch to Locked.
16. Close the door on the server, and lock it.
24.1.2.2

Deletion

Follow the addition instructions in reverse order.
24.2

Addition and Deletion of Power Cabinet

The three procedures listed below can be used. Regardless of the procedure used, see the
power cabinet installation procedure explained in the SPARC Enterprise M8000/M9000
Servers Installation Guide.
Adding or deleting a power cabinet for the M8000 server with three-phase dual power
feed configured
Chapter 24
From a console that is connected to XSCF, execute the poweron -a command of
XSCF.
4-22, and the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF
Addition and Deletion of a RDPF Option, Power Cabinet, and M9000 Expansion Cabinet 24-13
Section 4.4.2, "Powering the Server On" on