3. Use the activate-volume command to activate the RAID volume.
{0} ok 0 activate-volume
Volume 0 is now activated
{0} ok show-volumes
Volume 0 Target 0 Type IM (Integrated Mirroring)
Degraded Enabled Resync In Progress
2 Members
Disk 1
Primary Online
Target 8
Disk 0
Secondary Online Out Of Sync
Target 1
Note – If there are multiple RAID volumes, they must be activated in descending order, as
shown below.
{0} ok 1 activate-volume
Volume 1 is now activated
{0} ok 0 activate-volume
Volume 0 is now activated
FUJITSU MBD2300RC 3702
FUJITSU MBD2300RC 3702
Chapter 13
585805824 Blocks, 299 GB