Cold Replacement - Fujitsu SPARC Enterprise M8000 Service Manual

Oracle
Hide thumbs Also See for SPARC Enterprise M8000:
Table of Contents

Advertisement

13. Turn on the power to the relevant domain.
From a console that is connected to XSCF, execute the poweron -d command of
XSCF.
For details of the power-on operation, see
page
User's Guide.
14. Start up domains as necessary.
15. Close the door on the server and lock it.
14.4

Cold Replacement

The procedure is as follows.
1. Unlock and open a door of the server. (See
Caution – Before touching a FRU or dummy (filler) unit, see
Precautions" on page 1-9
result in serious damage to operating domains.
2. Change the mode switch setting on the OPNL from the Locked to Service.
3. Use one of the following methods to stop (power off) all domains at once.
The OS shutdown processing is executed for all the domains, and then the power-off
processing is executed.
4. Confirm that the power-off processing is completed by confirming that the POWER
LED (green) on the operator panel is off.
14-12
SPARC Enterprise M8000/M9000 Servers Service Manual • October 2012
4-22, and the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF
and be sure to wear the antistatic wrist strap. Failure to do so might
Press and hold the POWER switch on the operator panel for at least four seconds.
From a console that is connected to XSCF, log in to XSCF, and execute the
poweroff -a command.
Section 4.4.2, "Powering the Server On" on
Chapter
5)
Section 1.4, "Antistatic