Calibration
procedure:
1)
Remove
the safety key
2)
Press and hold down the Start and Fast (speed up) buttons
with one hand and replace
the safety key
with the other. Continue
to hold the Start and Fast key until the window
displays
"Factory
settings",
then press the enter key.
3)
You will now be able to set the display to show Metric or English
settings.
To do this press the up or
down key to show which you want, then press enter.
4)
Make sure the wheel
size diameter
is 2.810 then press enter
5)
Adjust the minimum
speed (if needed)
to 0.5 and then press enter
6)
Adjust the maximum
speed (if needed)
to 12.0 and then press enter
7)
Adjust the maximum
elevation
(if needed)
to 15 and then press enter
8)
Press start to begin calibration.
The process
is automatic;
the speed will start up without warning
so do
not stand on the belt.
Adjusting
the speed sensor:
if the calibration
does not pass you may need to check the speed sensor alignment.
1
2)
3)
Remove
the motor cover hood by loosening
the 4 screws
that hold it in place (you do not need to
remove them completely).
The speed sensor
is located
on the left side of the frame, right next to the front roller pulley (the pulley
will have a belt around
it that also goes to the motor). The speed sensor
is small and black with a wire
connected
to it.
Make sure the sensor is as close as possible
to the pulley without
touching
it. You will see a magnet
on
the face of the pulley; make sure the sensor
is aligned
with the magnet.
There is a screw that holds the
sensor in place that needs to be loosened
to adjust the sensor.
Re-tighten
the screw when finished.
Maintenance
menu:
1)
Press and hold the Start, Stop and Enter key at the same time, until the display shows "Engineering
mode" (it may say maintenance
menu, depending
on version).
Press the Enter key.
2)
You can now scroll through
the menu using the up and down keys. Use the Stop key to return to
previous
menu selection.
The menu selections
are:
1) Calibration
(used to verify calibration)
2)
Factory
settings
(These should
not be changed
unless instructed by Sole service
department)
3)
Security
(This allows you to lock the console
keyboard)
4)
Functions
i.
Sleep
(turns sleep mode on or off)
ii.
Pause
(turns pause mode on or off)
iii.
Maintenance
(reset lube message
and odometer
readings)
iv.
Units
(set display to English
or Metric readings)
v.
Grade
return
(returns
the elevation
to lowest setting when pause is pressed)
5)
Display
test (lights all LED lights for testing)
6)
Key test (tests that all keys are functioning)
26