WARNING!
NEVER
use a ground fault circuit interrupt
(GFCI) wall outlet with this treadmill.
Large switching
currents
of the drive motor will trip GFCI type outlets,
as will any appliance
with a large motor.
Route the power cord away from any moving
part of the treadmill
including
the elevation
mechanism
and transport
wheels.
NEVER
remove any cover without
first disconnecting
AC power. If voltage
varies by ten percent
(10%) or more, the performance
of your treadmill
may be affected.
Such
conditions
are not
covered
under
your
warranty.
If you suspect
the voltage
is low, contact
your local power company
or a licensed
electrician
for proper testing.
NEVER
expose this treadmill to rain or moisture.
This product is NOT designed
for use outdoors,
near a pool or spa, or in any other high humidity
environment.
The temperature
specification
is
40 to 120 degrees
Fahrenheit,
and humidity
limit is 95%, non-condensing
(no water drops
forming on surfaces).
This product
must be grounded.
If the treadmill
should
malfunction
or breakdown,
grounding
provides
a path of least resistance
for electric
current,
reducing
the risk of electric
shock. This
product is equipped
with a cord having an equipment-grounding
plug. The plug must be plugged
into an appropriate
outlet that is properly
installed
and grounded
in accordance
with all local codes
and ordinances.
Circuit
breakers:
Some circuit breakers
used in homes are not rated for high inrush currents
that
can occur when a treadmill
is first turned on or even during normal use. If your treadmill is tripping the
house circuit breaker
(even though
it is the proper current rating) but the circuit breaker on the
treadmill
itself does not trip, you will need to replace the home breaker with a high inrush type. This is
not a warranty
defect. This is a condition
we as a manufacture
have no ability to control.
This part is
available
through
most electrical
supply stores.
Examples:
Grainger
part # 1 D237, or available
online at www.squared.com
part # QO120HM
DANGER
- Improper
connection
of the equipment-grounding
conductor
can result
in a risk
of electric
shock.
Check
with a qualified
electrician
or serviceman
if you
are in doubt
as to
whether
the product
is properly
grounded.
Do not modify
the plug
provided
with the product
if it will not fit the outlet;
have
a proper
outlet
installed
by a qualified
electrician.
This product is for use on a nominal
110-volt
circuit, and has a grounding
plug that looks like the
plug illustrated
below. A temporary
adapter
that looks like the adapter
illustrated
below may be
used to connect
this plug to a 2-pole receptacle
as shown below if a properly
grounded
outlet is not
available.
The temporary
adapter
should
be used only until a properly
grounded
outlet,
(shown
below) can be installed
by a qualified
electrician.
The green colored
rigid ear-lug,
or the like,
extending
from the adapter,
must be connected
to a permanent
ground such as a properly
grounded
outlet box cover. Whenever
the adapter
is used, it must be held in place by a metal
screw.
Grounded
Outlet
/
Grounding
Pin
Adapter
___"
Tab of
Grounding
Screw
./
Grounded
Outlet Box
$73/$77