Section 2: Framing & Clearances; Framing The Fireplace - Montigo P42DF Prestige Series Installation & Maintenance Manual

Prestige series residential fireplace
Hide thumbs Also See for P42DF Prestige Series:
Table of Contents

Advertisement

P42DF* Indoor Gas Fireplace
Section 2: Framing & Clearances
Frame in the enclosure for the unit with framing materials. The framed
opening for the assembled fireplace is 42" wide, x 42" high x 21 7/8"
deep, see Figure 2
.
NOTE: When constructing the framed opening, please ensure
there is access to install the gas line when the unit is installed.
See Figure 20.
Noncombustible
Stud
Figure 2. Framing dimensions, (Straight wall & Corner
Installation).
Combustible Header
Combustible Shelf
12" max.
RHS101
34 1/2"
27 1/2"
Figure 3. Combustible Framing for shelves over the fireplace,
Rear vent.
Combustible Header
Combustible Shelf
RHS101
17 1/2"
MEL Short
90° elbow
40 1/2"
Figure 4. Combustible Framing for shelves over the fireplace,
Top vent.
Page 6
Installation
0" clearance
to corners
59 3/4"
Note: When sheetrock is not used behind
the fireplace, framing depth 21 7/8" may
be reduced by 5/8".
Non Combustible
Stud 1/2" Above Top
9"
42"
Non Combustible
Stud 1/2" above top
50 1/2"
N.G. & L.P.
Top Vent
Min 1"
12" max.
96"
MI N
Rear
Vent
Figure 5. Non Combustible Framing for Top Vent or Rear
Vent, with alcove.
Ceilin g
Non-Combustibl e
Materials Only
Alcove
area over
Fireplac e
Non-combustible
header
3"
12"
door
opening
Floor
XG0195 - 030712.1