Montigo P42DF Prestige Series Installation & Maintenance Manual

Prestige series residential fireplace
Hide thumbs Also See for P42DF Prestige Series:

Advertisement

Installation & Maintenance Manual
DANGER
Read and understand this manual. Improper installation, adjustment, alteration,
service or maintenance can cause serious injury, property damage or even death.
For assistance or additional information consult a qualified installer, service
agency or the gas supplier.
Glass doors on gas fireplaces are extremely hot while the fireplace is on and
remain hot even after the fireplace has been turned off. Safety screens are
available and can reduce the risks of severe burns. Please keep children away
from the fireplace at all times.
C
XG0195
CAUTION
®
US
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
P42DF Indoor
Prestige Series
Residential
Fireplace
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other gas burning appliance. A fire or explosion my occur causing serious
injury, property damage or even death.
NOTICE
Installer: Leave this manual with the appliance. Do not remove.
Consumer: Retain this manual for maintenance and future reference. Do not Discard.
DANGER
Blank
IF YOU SMELL GAS
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not try to light any appliance.
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not touch any electrical switch; do not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Immediately call your gas supplier from a neighbor's phone. Follow the gas
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Blank
supplier's instructions.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
If you cannot reach your gas supplier, call the fire department.
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
falling objects
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
030712.1

Advertisement

Table of Contents
loading

Summary of Contents for Montigo P42DF Prestige Series

  • Page 1 Hazardous to the Danger of harming radiation Environment your hands XG0195 030712.1 Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248 Gas bottles Watch for Electricity Danger for cutter Entrapment hazard Battery hazard...
  • Page 2: Table Of Contents

    P42DF* Indoor Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance. Table of Contents Safety Alert Key Maintenance ................23 - 24 Introduction .................3 ▪...
  • Page 3: Safety Alert Key

    INTRODUCTION Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 4: Installation

    Should it be impossible to meet the venting requirements laid „ out in Section 3: Venting, please contact a local Montigo dealer regarding the use of a Montigo Power Vent. Lay out the Vent run; calculating the required elbows and straight „...
  • Page 5: Section 1: Installation Overview And Product Dimensions

    P42DF* Indoor Gas Fireplace Installation Section 1: Installation Overview and Product Dimensions Safety, as well as efficiency of operation, should be considered when Please review the Pre-Installation Checklist on Page 4 for general selecting the fireplace location. Select a location that does not interfere information on preparing for a successful installation of your fireplace.
  • Page 6: Section 2: Framing & Clearances

    P42DF* Indoor Gas Fireplace Installation Section 2: Framing & Clearances Frame in the enclosure for the unit with framing materials. The framed N.G. & L.P. opening for the assembled fireplace is 42" wide, x 42" high x 21 7/8" Top Vent Ceilin g deep, see Figure 2 Non-Combustibl e...
  • Page 7: Clearances

    P42DF* Indoor Gas Fireplace Installation Clearances Installing the Nailing Flange Extension When installing a shelf over the top of the fireplaces, the following Before installing the supplied nailing flange extension, fold tabs at bottom guidelines must be adhered to: of nailing flange to a 90 degree angle. For Rear Vent applications, the minimum clearance is 0"...
  • Page 8: Section 3: Venting

    Should it be impossible to ensure that the termination is the highest point or to Flue Cover Plate meet the venting guidelines laid out below please contact your Montigo Flue Gasket dealer to discuss power venting options.
  • Page 9: Section 3-2: Installing Pvtk-1

    P42DF* Indoor Gas Fireplace Installation Section 3-2: INSTALLING A ROOF MOUNTED DIRECT VENT PVTK1 TERMINATION (PVTK-1) Termination This section applies to installations where the direct vent termi- 2’ min. nation will be roof mounted. Support ring VENTING LAYOUT Selection of components and details of venting lay out should Support plate 32’...
  • Page 10 P42DF* Indoor Gas Fireplace Installation PVTK1 Termination PEXT Sections Support plate 32’ max Support ring 12” Max. Figure 9c. Rear vent, Roof mounted venting (1 = 90° bend). Page 10 XG0195 - 030712.1...
  • Page 11: Section 3-3: Installing Wall Mounted Direct Vent Termination

    P42DF* Indoor Gas Fireplace Installation Section 3-3: INSTALLING A WALL MOUNTED 4). Installation of termination from inside structure DIRECT VENT TERMINATION A Termination with a MOSR Frame is installed from the inside of the structure. These are commonly used in high-rise construction. This section applies to installations where the direct vent termination will be wall mounted.
  • Page 12: Section 3-3-1: Venting Layout Wall Mounted Termination

    44 ” All measurements for vertical or horizontal runs are measured „ please contact a local Montigo from center of the vent pipe. dealer for Power Venting options. Venting runs must fall within the limits set by the venting graph, „...
  • Page 13 42 ” If your installation does not fall within 27.5 ” the venting parameters, please contact a local Montigo dealer for 12 ” Power Venting options. Figure 14. Rear Vent Venting Graph for NG and LP wall mounted terminations.
  • Page 14 P42DF* Indoor Gas Fireplace Installation 45° or less Corner Installation. 45° Corner Installation. Use an PTO-4 termination and an PFL-1 or PFL-2 (12" or 24" Attach an PEL-45 (45° elbow) directly onto the flue collar. Cut the PXT- compressed length) and a frame, if appropriate. Flex may be turned 20 to suit, and attach it to the PEL-45.
  • Page 15: Section 3-3-2: Venting Components

    PEXT - 1 (12" f/m Section) possible hot spots. PEXT - 2 (24" f/m Section) Montigo recommends the use of a flex section for the final pipe PEXT - 3 (36" f/m Section) „ PEXT - 4 (48" f/m Section) connected directly to the fireplace offering greater flexibility of PEXT - 6 (72"...
  • Page 16: Section 3-3-3:Heat Shields

    P42DF* Indoor Gas Fireplace Installation Section 3-3-3: Heat Shields Installing a Wall Mounted RHS101 Heat shield. The RHS101 Heat shield MUST be used where the RHS8 Termination (Figure 16 and 16a) CANNOT be used. Use the RHS101 where any Installing a Wall Mounted RHS8 Heat shield of the dimensions are within the parameters shown, figure 16a.
  • Page 17: Section 4: Wiring

    P42DF* Indoor Gas Fireplace Installation Section 4: Wiring Models P42DFNI Black P42DFLI Power Supply 110VAC, 5amp Green Ground White WALL SWITCH Bulbs Fan Speed Control Receptacle Thermo Sensor Green Green Control Valve Receptacle 120 Vac INPUT Adapter Green Receiver 14 Battery Holder w/ Switch REMOTE...
  • Page 18: Section 5: Installing The Gas Line

    To check pressures, control valves have a provision to remove „ a 1/8” N.PT. plug to be fitted with a hose barb. Montigo requires a service shut off valve be located in an „ accessible location to isolate the gas supply.
  • Page 19: Finishing

    P42DF* Indoor Gas Fireplace Installation Finishing Around the Fireplace Mantels & Surrounds Non-combustible mantels and mouldings may be safely installed over NOTE: National Canadian Gas Association mantel test requirements the top and on the front of the fireplace provided that they do not project are for fire hazard prevention to combustible materials.
  • Page 20: Removing The Door

    P42DF* Indoor Gas Fireplace Installation Section 7: Installing & Removing the Door Removing the door: Step 5: The P42DF* doors are removed in a few simple steps. Follow these Ensure the tool is firmly in instructions below to remove the Horizontal access panel, unlatch the the lower end of the slot, door buckles and, remove the door.
  • Page 21: Section 8: Installing The Accessories

    P42DF* Indoor Gas Fireplace Installation Section 8: Installing the Accessories Installing the Firestones The P42DF* is supplied with firestones. Remove the Door as shown in the previous Instruction. Follow these instructions to ensure all parts are removed or replaced as required. Once the glass door is removed place the firestones randomly across the pan and the burners as described in Figure 24 to 24f.
  • Page 22: Operation

    P42DF* Indoor Gas Fireplace Operation SIT Proflame Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: Models WARNING P42DFNI P42DFLI If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 23: Maintenance

    P42DF* Indoor Gas Fireplace Maintenance Lighting Instructions See page 22. General Pilot Burner Adjustment. Have the fireplace and installation inspected yearly. The inspection must 1. Locate Pilot Adjustment Screw. (See figure 25) include, but is not limited to, the following: 2.
  • Page 24: Replacing Light Bulbs

    If your fireplace still does not operate correctly, consult your local Montigo dealer. All service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Page 24...
  • Page 25: Appendix

    P42DF* Indoor Gas Fireplace Appendix Appendix A: Venting Terminations Location Canada* USA** clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches clearance to top of doors or operable windows 12 inches 12 inches 9 inches 12 inches clearance to sides or bottom of door or operable windows...
  • Page 26: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 27: State Of Massachusetts

    P42DF* Indoor Gas Fireplace Appendix Appendix C: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by adding the following additional requirements:...
  • Page 28 P42DF Single Sided Gas Fireplace Ferndale, Washington Langley, British Columbia TF: 1.800.789.6236 TF: 1.800.378.3115 FX: 1.866.3000.0927 FX: 1.604.607.6462 XG0195 - 030712.1...

This manual is also suitable for:

P42dfniP42dfli

Table of Contents