Section 4: Wiring
Models
P42DFNI
P42DFLI
Thermo
Receiver 14
Battery Holder
w/ Switch
ON/REMONTE/OFF
Receiver 14
Pin Connector
Figure 18. Wiring diagram for P42DF with SIT Proflame Electronic Ignition
Note:
If any of the original wire supplied with the appliance is replaced,it
must be replaced with the same type, or its equivalent
XG0195 -030712.1
Installation
Bulbs
Blk
Sensor
Blk
Blk
Fan
Wht
Wht
Fan
Adapter
Blk
REMOTE
Receiver 14
Battery Holder
Top View
RECEIVER
Remote control
1
1
Black
Red
Green
White
Red
6
6
Fan Speed
Fan
Control
Receptacle
Blk
Blk
Wht
Wht
Green
Green
Control Valve
Receptacle
120 Vac INPUT
Blk
Wht
AC
Green
(Not Used)
SPLIT FLOW
Chassis
connection
GROUND
Figure 19. Electrical connection access.
P42DF* Indoor Gas Fireplace
Blk
Wht
Orange
Pilot
Green
885 Valve
IPI/CPI
7.5V DC
(CPI / IPI MODE
Output
Not Used)
1
5
2 "
6 5/8
1
2
8 "
L2
Power Supply
110VAC, 5amp
Ground
L1
WALL SWITCH
Battery
Holder
4 x 1.5V
AA Type
7
8 "
Page 17