Montigo P42DF Installation & Maintenance Manual

Prestige series residential fireplace
Hide thumbs Also See for P42DF:

Advertisement

Installation & Maintenance Manual
DANGER
Read and understand this manual. Improper installation, adjustment, alteration,
service or maintenance can cause serious injury, property damage or even death.
For assistance or additional information consult a qualified installer, service
agency or the gas supplier.
Glass doors on gas fireplaces are extremely hot while the fireplace is on and
remain hot even after the fireplace has been turned off. Safety screens are
available and can reduce the risks of severe burns. Please keep children away
from the fireplace at all times.
C
XG0195
CAUTION
®
US
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
P42DF Indoor
Prestige Series
Residential
Fireplace
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other gas burning appliance. A fire or explosion my occur causing serious
injury, property damage or even death.
NOTICE
Installer: Leave this manual with the appliance. Do not remove.
Consumer: Retain this manual for maintenance and future reference. Do not Discard.
DANGER
Blank
IF YOU SMELL GAS
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not try to light any appliance.
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not touch any electrical switch; do not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Immediately call your gas supplier from a neighbor's phone. Follow the gas
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Blank
supplier's instructions.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
If you cannot reach your gas supplier, call the fire department.
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
falling objects
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
030712

Advertisement

Table of Contents
loading

Summary of Contents for Montigo P42DF

  • Page 1 Hazardous to the Danger of harming radiation Environment your hands XG0195 030712 Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248 Gas bottles Watch for Electricity Danger for cutter Entrapment hazard Battery hazard...
  • Page 2: Table Of Contents

    P42DF* Indoor Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance. Table of Contents Safety Alert Key Maintenance ................22 - 24 Introduction .................3...
  • Page 3: Safety Alert Key

    INTRODUCTION Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 4: Installation

    Installation Checklist IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS Determine the desired install location of your fireplace. The P42DF* Direct Vent fireplace must be installed in accordance with „ these Instructions. Carefully read all the Instructions in this manual See Section 1, Dimensions on Page 5, and refer to the Framing „...
  • Page 5: Installation Overview And Product Dimensions

    Direct Vent installation. The P42DF* fireplace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumbing. Safety, as well as efficiency of operation, should be considered when The fireplace dimensions are shown below: 4 "...
  • Page 6: Framing & Clearances

    P42DF* Indoor Gas Fireplace Installation Section 2: Framing & Clearances Frame in the enclosure for the unit with framing materials. The N.G. & L.P. framed opening for the assembled fireplace is 42" wide, x 42" high x Top Vent Ceilin g 21 1/4"...
  • Page 7: Venting

    See Section 3-1 for converting the unit from top vent to rear vent. Section 3-1: CONVERTING TO REAR VENT Use the following instructions to convert an P42DF* for Rear Vent use: 1. Remove the Rear flue cover and gasket (5" and 8") on the flue outlet, as shown in Figure 7.
  • Page 8: Section 3-2: Installing Pvtk-1

    P42DF* Indoor Gas Fireplace Installation PVTK1 Section 3-2: INSTALLING A ROOF MOUNTED Termination DIRECT VENT TERMINATION (PVTK-1) 2’ min. This section applies to installations where the direct vent termi- nation will be roof mounted. Support ring Section 3-2-1: VENTING LAYOUT Support plate 32’...
  • Page 9: Section 3-2-2: Venting Components

    12” any possible hot spots. Max. Montigo recommends the use of a flex section for the final pipe „ connected directly to the fireplace offering greater flexibility of installation and absorption of movement.
  • Page 10: Section 3-3: Installing Wall Mounted Direct Vent Termination

    P42DF* Indoor Gas Fireplace Installation Section 3-3: INSTALLING A WALL MOUNTED 4). Installation of termination from inside structure DIRECT VENT TERMINATION A Termination with a MOSR Frame is installed from the inside of the structure. These are commonly used in high-rise construction.
  • Page 11: Section 3-3-1: Venting Layout Wall Mounted Termination

    „ from center of the vent pipe. Venting runs must fall within the limits set by the venting graph, Figure 10a. P42DF* NG Top Vent Venting Graph for wall mounted terminations. „ see Figure 10 or 10a. 44" Min. (NG) Wall mounted Terminations 12 Min.
  • Page 12 Flex may be turned IMPORTANT: to obtain desired degree of angle required but must not exceed 45°. Corner Installation is available for P42DF Top Vent Units Only. Ensure minimum Vertical Venting Height of 48" is maintained in corner installations.
  • Page 13 27 1/2” within non-shaded area. Figure 13c. Rear Vented, wall mounted Multi-elbow termination installation. Installation for P42DF* must have a minimum vertical rise of 46".The vent run must comply with the Venting Graph for Rear vent, wall mounted terminations, Figure 13.
  • Page 14: Section 3-3-2: Venting Components

    P42DF* Indoor Gas Fireplace Installation ■ Montigo recommends the use of a flex section for the final pipe Section 3-3-2: VENTING COMPONENTS connected directly to the fireplace offering greater flexibility of The following components and associated Montigo part numbers are installation and absorption of movement.
  • Page 15: Section 3-3-3:Heat Shields

    P42DF* Indoor Gas Fireplace Installation Section 3-3-3: Heat Shields Installing a Wall Mounted RHS101 Heat shield. The RHS101 Heat shield MUST be used where the RHS8 Termination (Figure 14 and 14a) CANNOT be used. Use the RHS101 where any Installing a Wall Mounted RHS8 Heat shield of the dimensions are within the parameters shown, figure 14a.
  • Page 16: Wiring

    P42DF* Indoor Gas Fireplace Installation Section 4: Wiring Models P42DFNI P42DFLI Figure 15. Wiring for the SIT IPI Wiring Schematic Wiring for Fan Kit Installations in Canada must be electrically grounded in accordance 2 " with CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes.
  • Page 17: Installing The Gas Line

    (Natural Gas or Propane shown by "N" or "L" in your model number If gas type is not compatible, contact your local Montigo representative to purchase a conversion kit. Conversion kits must be installed by a qualified service 4 "...
  • Page 18: Finishing

    P42DF* Indoor Gas Fireplace Installation Section 6: Finishing Installing the Nailing Flange Extension Finishing Around the Fireplace Once the fireplace is placed into the rough framed opening, and the Combustible mantels and mouldings may be safely installed over the supplied steel lintel is in place, (Part No. H38074) (see Figure 2), top and on the front of the fireplace provided that they do not project beyond shaded area shown in Figure 18.
  • Page 19: Removing The Door

    Section 7: Installing & Removing the Door Removing the door: Step 5: The P42DF* doors are removed in a few simple steps. Follow these Ensure the tool is firmly in below to remove the Horizontal access panel, unlatch the door buckles the lower end of the slot, and, remove the door.
  • Page 20: Installing The Accessories

    Installation Section 8: Installing the Accessories Installing the Firestones The P42DF* is supplied with firestones. Remove the Door as shown in the previous Instruction. Follow these instructions to ensure all parts are removed or replaced as required. Once the Trim and glass door is removed place the firestones randomly across the pan and the burners as described in Figure 22 to 22f.
  • Page 21: Operation

    P42DF* Indoor Gas Fireplace Operation Section: Proflame SIT Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING Models P42DFNI If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 22: Maintenance

    P42DF* Indoor Gas Fireplace Maintenance Lighting Instructions See page 21. General Have the fireplace and installation inspected yearly. The inspection must include, but is not limited to, the following: A visual check of the entire vent system and termination. „...
  • Page 23: Replacing Light Bulbs

    P42DF* Indoor Gas Fireplace Maintenance Replacing Light Bulbs The P42DF* light bulbs can be replaced in a few simple steps. Follow the directions for removing the door on page 21. Once the door has successfully been removed, proceed with figures 23 - 23b.
  • Page 24: Troubleshooting

    P42DF* Indoor Gas Fireplace Maintenance Troubleshooting: (IPI System). Replacement Parts List The following is a troubleshooting chart of possible problems: P42DF* RGC3033 NG Gas Valve with Stepper Motor PROBLEM SOLUTION RGC3034 LP Gas Valve with Stepper Motor Pilot won't ignite or spark.
  • Page 25: Appendix

    P42DF* Indoor Gas Fireplace Appendix Appendix A: Termination Locations A = clearance to the termination frame above grade, veranda, porch, deck, or Q = clearance above a roof [24 inches (61 cm) minimum] balcony [16 inches (41 cm) minimum] R = clearance to adjacent walls and neighboring buildings [18 inches (46 cm)
  • Page 26: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 27: State Of Massachusetts

    P42DF* Indoor Gas Fireplace Appendix Appendix C: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by...
  • Page 28 P42DF Flush Face Single Sided Gas Fireplace Ferndale, Washington Langley, British Columbia TF: 1.800.789.6236 TF: 1.800.378.3115 FX: 1.866.3000.0927 FX: 1.604.607.6462 XG0195 - 030712...

This manual is also suitable for:

P42dfniP42dfli

Table of Contents