DANGER
Read and understand this manual. Improper installation, adjustment, alteration,
service or maintenance can cause serious injury, property damage or even death.
For assistance or additional information consult a qualified installer, service
agency or the gas supplier.
Glass doors on gas fireplaces are extremely hot while the fireplace is on and
remain hot even after the fireplace has been turned off. Safety screens are
available and can reduce the risks of severe burns. Please keep children away
from the fireplace at all times.
XG0196
CAUTION
®
C
US
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
P52DF Indoor
Prestige Series
Residential
Fireplace
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other gas burning appliance. A fire or explosion my occur causing serious
injury, property damage or even death.
NOTICE
Installer: Leave this manual with the appliance. Do not remove.
Consumer: Retain this manual for maintenance and future reference. Do not Discard.
DANGER
Blank
IF YOU SMELL GAS
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not try to light any appliance.
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not touch any electrical switch; do not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Immediately call your gas supplier from a neighbor's phone. Follow the gas
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Blank
supplier's instructions.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Flammable materials
Explosion risk
falling objects
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
If you cannot reach your gas supplier, call the fire department.
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
falling objects
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Hot surface
Danger of entrapment
Environment
Danger of death
your hands
General Warning
Laser Radiation
Biohazard
Oxidising
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
102512.1

Advertisement

Table of Contents
loading

Summary of Contents for Montigo P52DF

  • Page 1 Hazardous to the Danger of harming radiation Environment your hands XG0196 102512.1 Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248 Gas bottles Watch for Electricity Danger for cutter Entrapment hazard Battery hazard...
  • Page 2: Table Of Contents

    P52DF* Indoor Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance. Table of Contents Safety Alert Key Operation ............... 22 Introduction ..............
  • Page 3: Safety Alert Key

    INTRODUCTION Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 4: Installation

    P52DF* Indoor Gas Fireplace Installation IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS Installation Checklist The Prestige Series P52DF* Direct Vent fireplace must be Determine the desired install location of your fireplace. „ installed in accordance with these Instructions. Carefully See Section 1, Dimensions on Page 5, and refer to „...
  • Page 5: Installation Overview And Product Dimensions

    Select a location that does not interfere The P52DF* fireplace may be installed in any location with room traffic, has adequate ventilation and offers an that maintains proper clearances to air conditioning ducts, accessible path for Direct Vent installation.
  • Page 6: Framing & Clearances

    P52DF* Indoor Gas Fireplace Installation Section 2: Framing & Clearances 20” Max Frame in the enclosure for the unit with framing materials. The framed opening for the assembled fireplace is 52" wide, Combustible Header x 43" high x 24 1/2" deep, see Figure 2 Heat Sheild 26”...
  • Page 7: Clearances

    Clearance to the insulated flange is 1". Installing The Standoffs 4" To avoid elevated mantel temperatures, all P52DF* gas fireplaces are required to have the supplied standoffs installed. Figure 6d. Securing the Nailing Flange Extension. The fireplace is supplied with two standoffs. Bend and install...
  • Page 8: Venting

    Section 3-1: CONVERTING TO REAR VENT Use the following instructions to convert a P52DF* from Use the following instructions to convert a P52DF* for Rear 5"/ 10" to 5"/ 8" venting for Top or Rear Vent use outside Vent use: of 8 feet vertically from the unit: 1.
  • Page 9: Section 3-2 Installing Pvtk-1

    P52DF* Indoor Gas Fireplace Installation Section 3-2: InSTaLLIng a ROOF MOUnTED DIRECT VEnT TERMIna- TIOn (PVTK-1) for 5"/8" PVTK1 This section applies to installations where the direct vent termination Termination will be roof mounted. 2’ min. VEnTIng LaYOUT Selection of components and details of venting lay out should adhere to...
  • Page 10 P52DF* Indoor Gas Fireplace Installation PVTK1 Termination PEXT Sections 8’ min. Support plate 32’ max Support ring 12” Max. Figure 8c. (5"/8") Rear vent, Roof mounted venting (1 = 90° bend). Page 10 XG0196 - 102512.1...
  • Page 11: Termination

    P52DF* Indoor Gas Fireplace Installation Section 4-3-2: Section 3-3: INSTALLING A WALL MOUNTED INSTALLING A WALL MOUNTED DIRECT VENT TERMINATION (5"/8") DIRECT VENT TERMINATION (5"/10") This section applies to installations where the direct vent This section applies to installations where the direct vent termination will be wall mounted with 5"...
  • Page 12: Section 3-4: Venting Layout Wall Mounted Termination

    If your installation does not fall within the venting graph parame- Notes Wall Mounted Terminations: 5"/8" TOP VENT ters, please contact a local Montigo All measurements for vertical or horizontal runs are Dealer for Power Venting options. „...
  • Page 13 A faulty seal on the door gasket ters, please contact a local Montigo and/or explosion ports will result in products of combustion leaking into Dealer for Power Venting options.
  • Page 14 P52DF* Indoor Gas Fireplace Installation 45° Corner Installation. 45° or less Corner Installation. Attach an REL-45 (45° elbow) directly onto the flue collar. Use an RTO-4 termination and an RFL-4 (48" compressed Cut the RXT-20 to suit, and attach it to the REL-45. Slide length) and a frame, if appropriate.
  • Page 15: Section 3-5 Venting Components

    REXT - 4 (48" f/m Section) and avoid any possible hot spots. REXT - 6 (72" f/m Section) Montigo recommends the use of a flex section for the „ E - Elbows PEL-90MM (m/m 90º Elbow) final pipe connected directly to the fireplace offering PEL-90FF ( f/f 90º...
  • Page 16: Section 3-6: Heat Shields

    P52DF* Indoor Gas Fireplace Installation Section 3-6: Heat Shields Installing a wall Mounted RHS 102 Heat shield Installing a wall Mounted RHS 104 Heat shield. The RHS102 Heat Shield (Figure 16 and 16a) MUST be The RHS104 Heat shield MUST be used in conjunction with used in all cases where the venting passes through a wall.
  • Page 17: Wiring

    WHITE ON/OFF BLACK CONTROL Figure 17. Wiring Diagram for P52DF with SIT Proflame 2 Electronic Ignition Installations in Canada must be electrically grounded in accordance with CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes. Installations in the USA must be grounded in accordance 5½”...
  • Page 18: Section 5: Installing The Gas Line

    ■ Verify that your fireplace is compatible with your available gas type. (Natural Gas or Propane shown by "N" or "L" in your model number ■ If gas type is not compatible, contact your local Montigo representative to purchase a conversion kit. 1¼”...
  • Page 19: Finishing

    P52DF* Indoor Gas Fireplace Installation Section 6: Finishing Mantels & Surrounds Finishing around the Fireplace NOTE: National Canadian Gas Association mantel test Non-combustible mantels and mouldings may be safely requirements are for fire hazard prevention to combustible installed over the top and on the front of the fireplace materials.
  • Page 20: Installing And Removing The Door

    Section 7: Installing & Removing the Door Removing the door: Step 5: The P52DF* doors are removed in a few simple steps. Ensure the tool is firmly Follow these below to remove the Horizontal access panel, in the lower end of unlatch the door buckles and, remove the door.
  • Page 21: Section 8: Installing The Accessories

    Installation Section 8: Installing the Accessories Installing the Firestones The P52DF* is supplied with firestones. Remove the Door as shown in the previous Instruction. Follow these instructions to ensure all parts are removed or replaced as required. Once the glass door is removed place the firestones randomly across the pan and the burners as described in Figure 23 to 23f.
  • Page 22: Operation

    P52DF* Indoor Gas Fireplace Operation SIT Proflame 2 Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING! If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 23: Maintenance

    P52DF* Indoor Gas Fireplace Maintenance General Pilot Burner Adjustment. Have the fireplace and installation inspected yearly. The 1. Locate Pilot Adjustment Screw. (See figure 24) inspection must include, but is not limited to, the following: 2. Adjust pilot screw to provide properly sized flame as •...
  • Page 24: Replacing Light Bulbs

    If your fireplace still does not operate correctly, consult your local Montigo dealer. All service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Page 24...
  • Page 25: Appendix

    P52DF* Indoor Gas Fireplace Appendix Appendix A: Venting Terminations Location Canada* USA** 12 inches 12 inches clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches clearance to top of doors or operable windows...
  • Page 26: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 27: State Of Massachusetts

    P52DF* Indoor Gas Fireplace Appendix Appendix C: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft.
  • Page 28: Wiring Diagram With Power Vent

    BROWN WHITE SWITCH YELLOW BLUE YELLOW WHITE Lights BLACK ON/OFF Figure 26. Wiring Diagram for P52DF with SIT Proflame 2 Electronic Ignition with Power Vent Note: Power Vent Kit required. Contact your local Montigo Dealer. Page 28 XG0196 - 102512.1...
  • Page 29 P52DF* Indoor Gas Fireplace Notes Page 29 XG0196 -102512.1...
  • Page 30 P52DF Single Sided Gas Fireplace Ferndale, washington Langley, British Columbia TF: 1.800.789.6236 TF: 1.800.378.3115 FX: 1.866.3000.0927 FX: 1.604.607.6462 XG0196 - 102512.1...