RP418, RP818 Electric/Pneumatic Relay

RP418 & RP818 Typical Piping and Wiring
RP418 OR
RP818
EXHAUST
2
SUPPLY
1
AIR
3
DAMPER
OPERATOR
Type: Electric / Pneumatic Relay
Dimensions, Approximate: 2 7/8 in. high x 3 13/16 in. wide x 1 1/4 in.
deep (73 mm high x 97 mm wide x 32 mm deep)
Airflow Usage: 0.42 scfm (200 mL/s) at 20 psi (138 kPa) supply with 1
psi (7 kPa) pressure drop
Air Connections: Barbed fitting for 1/4 in. O.D. plastic tubing
Capacity: 0.075 Cv minimum
Operation: Energized: ports 1 and 3 connected, port 2 blocked
De-energized: ports 2 and 3 connected, port 1 blocked
Operating Humidity Range (% RH): 5 to 95% RH
Product Number
Mounting
RP418A1008
Surface
RP418A1057
Surface
RP418A1065
Surface
RP418A1073
Surface
RP418A1081
Surface
RP418A1099
Surface
RP418A1107
Surface
RP418B1014
Panel mount
RP418B1022
Panel mount
RP418B1030
Panel mount
RP418B1048
Panel mount
RP418B1055
Panel mount
RP418B1071
Panel mount
RP818A1004
Surface
RP818B1002
Panel mount
RP818B1010
Panel mount
52
customer.honeywell.com
VOLTAGE
SUPPLY
FAN
SWITCH
FAN MOTOR
DAMPER
M5429B
Voltage rating
Voltage rating
at 50 Hz
at 60 Hz
208 Vac
120 Vac
440 Vac
480 Vac
277 Vac
208 Vac
220 Vac
240 Vac
110 Vac
120 Vac
208 Vac
240 Vac
120 Vac
440 Vac
480 Vac
208 Vac
110 Vac
120 Vac
24 Vac
24 Vac
24 Vac
Electrically operated pneumatic switches used to interlock an
electrical system and a pneumatic control system. Replacement
devices are available for Johnson, Powers, Robertshaw, Barber-
Colman, and older Honeywell devices.
Usable as a diverting relay, a selector relay, or a stop and bleed
relay.
Mount and operate in any position.
Available with lead wires or junction box.
Line or low voltage models available.
Internal Connections
1
2
3
DEENERGIZED:
PORTS 2 AND
3 CONNECTED,
PORT 1 BLOCKED.
Temperature Range: 0 F to 100 F (-18 C to +38 C)
Maximum Safe Operating Pressure: 50 psi (340 kPa)
Approvals:
Canadian Standards Association: Canadian Standards Association
Listed: File No. LR50900
Canadian Underwriters Laboratories, Inc. Listed: File No. LR50900
Underwriters Laboratories, Inc. Component Recognized File:
MP1502, Vol. 11, Sec. 1
UL Listed: Guide Y10Z
Frequency
Electrical Connections
50 Hz
Junction Box and 15 in. (380 mm) leads
50 Hz
Junction Box and 15 in. (380 mm) leads
50 Hz; 60 Hz Junction Box and 15 in. (380 mm) leads
60 Hz
Junction Box and 15 in. (380 mm) leads
60 Hz
Junction Box and 15 in. (380 mm) leads
50 Hz; 60 Hz Junction Box and 15 in. (380 mm) leads
50 Hz; 60 Hz Junction Box and 15 in. (380 mm) leads
50 Hz
15 in. (380 mm) leads
50 Hz
15 in. (380 mm) leads
50 Hz
15 in. (380 mm) leads
50 Hz; 60 Hz 15 in. (380 mm) leads
60 Hz
15 in. (380 mm) leads
50 Hz; 60 Hz 15 in. (380 mm) leads
60 Hz
Junction Box and 15 in. (380 mm) leads
60 Hz
15 in. (380 mm) leads
50 Hz
15 in. (380 mm) leads
70-6925
1
2
3
ENERGIZED:
PORTS 1 AND
3 CONNECTED,
PORT 2 BLOCKED.
M5428
Includes
Junction Box
Junction Box
Junction Box
Junction Box
Junction Box
Junction Box
Junction Box
Junction Box

Hide quick links: