Location Requirements; Electrical Requirements - Whirlpool YACQ088XP0 Use & Care Manual

Table of Contents

Advertisement

Available languages

Available languages

IMPORTANT: Observe all governing codes and ordinances.
Check the location where the air conditioner will be installed.
Proper installation is your responsibility.
Make sure you have
everything necessary for correct installation.
The location should provide:
Grounded electrical outlet within 4 ft (122 cm) of where
the power cord exits the air conditioner.
NOTE: Do not use an extension cord.
Free movement of air to rooms to be cooled.
A large enough opening for the air conditioner. Installation
parts are supplied for double-hung
windows.
Adequate wall support for weight of air conditioner. Air
conditioner
weighs 56 Ibs (25 kg) to 80 Ibs (36 kg).
NOTE: Cabinet louvers must not be obstructed.
Air must be able
to pass freely through the cabinet louvers.
/
N
!. Cabinet louvers
Window
installation
Window opening measurements:
26 in. (66 cm) minimum to 38 in. (95.5 cm) maximum
opening width.
16 in. (40.6 cm) minimum opening height.
mm
B
V
A. 26 in. (66 cm) minimum
B. 16 in. (40.6 cm) minimum
Electrical
Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground
prong.
Do not use an adapter.
Do not use an extension
cord.
Failure
to follow
these
instructions
can result
in
death,
fire, or electrical
shock,
In the U.S. only: If codes permit and a separate ground wire is
used, it is recommended
that a qualified electrician determine
that the ground path is adequate.
Check with a qualified electrician if you are not sure air
conditioner
is grounded.
A three-wire, single-phase,
60-Hz, AC-only, electrical supply is
required on a separate circuit. A 15-amp time-delay fuse or
circuit breaker is required. Copper wire (14 gauge) is required.
The fuse size must not exceed the circuit rating specified on the
model and serial number label. The model and serial number
label is located on the right-hand side of the cabinet.
Specific electrical requirements are listed in the chart. Follow the
requirements for the type of plug on the power supply cord.
Power supply cord
Wiring requirements
plug outlet
115 volt (103.5 rain. -
126.5 max.)
(_
_
0-12 amperes
15-amp time-delay fuse or
circuit breaker
14 gauge copper wiring
Recommended
ground method
For your personal safety, this air conditioner must be grounded.
This air conditioner
is equipped with a power supply cord having
a grounded 3 prong plug. To minimize possible shock hazard, the
cord must be plugged into a mating, grounded 3 prong outlet,
grounded in accordance with all local codes and ordinances. If a
mating outlet is not available, it is the customer's
responsibility to
have a properly grounded 3 prong outlet installed by a licensed
installer.
It is the customer's
responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in
conformance
with National Electrical Code, ANSI/NFPA 70 -
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch
Park
Quincy, Massachusetts
02269