,_UJUSTMENT:
I LENS AND CCD READ POSITION ADJUSTMENT
I
1) Loosen the lens fixing screw and CCD board fixing screw.
2) Adjust the position of the lens and CCD board so that the waveform appears as shown in the figure below.
3) Fix the lens fixing screw and CCD board fixing screw.
l
KX-1-12UU
Oscilloscope setting
CH1 ........... 0.5 V/div
CH2 ........... 2 V/div
TIME .......... 1 ms
Trigger ....... CH2
Mode ......... AC
I o L;L;U board
Extension Cord
(Part No. PQZZ8K18Z)
*Never connect land "AMON"
f
CN405
©.__1
FTG
VID O'_-_
OSCILLOSCOPE
To point "FTG".__
To point "VID".
AG
To LED array for CCD Unit.
©
DG
f
CN406
(DIGITAL BOARD)
Extension cord (Part No. PQZZ2K12Z)
Lens
.
Lens fixing screws
WAVEFORM
MAX.
(for Lens)
MAX.
(for CCD Board)
CCD board fixing screws
- 79 -