Panasonic KX-F1200 Service Manual And Technical Manual page 78

Plain paper fax with 2-line digital answering system
Hide thumbs Also See for KX-F1200:
Table of Contents

Advertisement

KX-F1200
I
4. CCD ADJUSTMENTS
Perform the following adjustment after replacing lens and CCD board.
PREPARATION:
1) Remove the CCD unit from set. (Refer to page 73)
2)
3)
4)
5)
6)
7)
8)
9)
Make oscilloscope
connections as shown in next page.
Attach the CCD TOOL on the CCD unit.
Connect between CCD unit and digital board with extension cord (Part No. PQZZ8K18Z). (Refer to next page).
Connect between LED array and digital board with extension cord (Part No. PQZZ2K12Z). (Refer to next page).
Connect AC cord.
Press the MENU button.
Press the #,9,0,0,0, and w buttons.
Press the 5,5 and 5 buttons.
Notes:
1) When replacingthe lens,pay attentionto the
markings on the lens are whiteand yellow.
The numberofthe CCD spacersto use differs
dependingon the markingas follows.
* Refer to page 180 for the locationofthe CCD
spacer.
2) Install the lens so that the marking (White or Yellow) on it is
upper side.
3) Do not touch the glass face of the lens with the bare hands.
Cleaning:
If the lens is dirty, clean it with a dry soft cloth.
Marking on the lens
White
Yellow
Number of CCD Spacer
0 (not used)
1
Lens
CCD Tool
(PQZZF500M)
CCD Unit
Note:
Please adjust with covering topside of the lens by hands in order not to let in outdoor daylight.