Selecting the proper location for your washer improves
performance and minimizes noise and possible washer "walk."
Your washer can be installed under a custom counter, or in a
basement, laundry room, closet, or recessed area. See "Drain
System."
Companion appliance location requirements should also be
considered.
Proper installation is your responsibility.
You will need
A water heater set to deliver 120°F (49°C) water to the
washer.
A grounded electrical outlet located within 6 ft (1.8 m) of
where the power cord is attached to the back of the washer.
See "Electrical Requirements."
Hot and cold water faucets located within 4 ft (1.2 m) of the
hot and cold water fill valves, and water pressure of
20-100 psi (137.9-689.6
kPa).
A level floor with a maximum slope of 1" (2.5 cm) under
entire washer. Installing the washer on soft floor surfaces,
such as carpets or surfaces with foam backing, is not
recommended.
A sturdy and solid floor to support the washer with a total
weight (water and load) of 400 Ibs (180 kg).
Do not operate your washer in temperatures
below 32°F (0°C).
Some water can remain in the washer and can cause damage in
low temperatures.
Installation
clearances
The location must be large enough to allow the washer door
to be fully opened.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
Additional spacing of 1" (2.5 cm) on all sides of the washer is
recommended
to reduce noise transfer.
Companion appliance spacing should also be considered.
Washer Dimensions
50W'
(128.3 crn)
27 _
(68.6crn)
Recommended
installation
spacing for custom
undercounter
installation
The dimensions
shown are for the recommended
spacing.
Custom undercounter
installation - Washer only
39"rain.
(99.0 crn)
4,
1"
--._
27",--,_1_-
1"
(2.5 crn)
'
(68.6 cm)
'
(2.5 cm)
Recommended
installation
spacing for recessed or
closet installation,
with or without
a pedestal
The dimensions
shown are for the recommended
spacing.
Recessed area or closet installation
34"'
(86.4 cm)
,,,,,,,,,,,,=-_
_
b_
I1"t_ 31w' -_14"I_-
(2.3crn) (80 cm) (10.2cm)
A
48 in.2*__
_-
(316crn 2}
24 iil. 2 * -
_
_
(155cm2)
_f
3"
(7,6crn)
3"
(7.6cm)
7
A. Side view - closet or confined area
B. Closet door with vents
* Min. top and bottom air openings for closet door.
Recessed or closet installation - Washer on pedestal
1" _
,,_--
2T' ---_,- ._-- 1"
(2.8 cm)
(68.6 crn)
(2.3 crn)
A
--
18" rain. _
(45.7crn)
I1"I_ 31,/_" _,-I4"
(2.8cm) (80cm) (10.2cm}
B
A. Recessed area
B. Side view - closet or confined area