  • Page 1 Sun StorageTek ATCA 4Gb FC Dual Port HBA Installation Guide For HBA Models SG-XPCIE2FC-ATCA-Z, SG-PCIE2FC-ATCA-Z, SG-XPCIE2FC-ATCA-N, and SG-PCIE2FC-ATCA-N Part No. 820-2217-13 April 2010, Revision A...
  • Page 2 Copyright © 2008, 2010, Oracle and/or its affiliates. All rights reserved. This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual property laws. Except as expressly permitted in your license agreement or allowed by law, you may not use, copy, reproduce, translate, broadcast, modify, license, transmit, distribute, exhibit, perform, publish, or display any part, in any form, or by any means.
  • Page 3: Table Of Contents

    Contents Preface v HBA Overview 1 Kit Contents 1 HBA Features and Specifications 1 Operating System Requirements 3 System Interoperability 3 Host Platform Support 4 Storage System Support 4 Fibre Channel Switch Support 4 Software Support 5 Hardware Installation and Removal 7 Observing ESD and Handling Precautions 7 Installing the Hardware 8 ▼...
  • Page 4 Removing the Hardware 15 ▼ To Prepare the HBA for Hot-Plug Removal Using the Module Handle 15 ▼ To Prepare the HBA for Hot-Plug Removal (Solaris OS) 15 ▼ To Remove the HBA Hardware 16 HBA Software Installation 17 Installing Software for the Solaris OS 17 ▼...
  • Page 5: Preface

    Preface This installation guide describes how to install and remove Oracle’s Sun StorageTek ATCA 4Gb FC dual port host bus adapter (HBA). It also explains how to verify the driver version and install any necessary patches. This document is written for technicians, system administrators, application service providers (ASPs), and users who have advanced experience troubleshooting and replacing hardware.
  • Page 6 Accessing Related Documentation The document listed in this section is available at: http://docs.sun.com/source/819-0139/ Title Part Number Solaris Fibre Channel and Storage Multipathing Administration Guide 819-0139 Documentation, Support, and Training Sun Function Documentation http://docs.sun.com Support http://www.sun.com/support/ Training http://www.sun.com/training/ Note – Prior to contacting Oracle support, record the HBA serial number in a safe location.
  • Page 7: Hba Overview

    C H A P T E R HBA Overview This chapter provides a basic overview of Oracle’s Sun StorageTek ATCA 4Gb FC Dual Port host bus adapter (HBA), which uses Emulex technology. This chapter also describes the various operating systems, host platforms, storage, and infrastructure configurations that support the HBA.
  • Page 8 HBA Features and Specifications TABLE 1-1 Feature Description AMC connector PCI signaling environment PCI Express x4 (4 active lanes) PCI transfer rate (maximum) PCI Express Generation One (2.5 Gbits/sec) x4 Number of FC buses Number of devices supported 126 devices per FC loop; 510 devices in Fabric mode FC bus type (external) Fiber-optic media, short-wave, multi-mode fiber (400-M5- SN-S)
  • Page 9: Operating System Requirements

    Operating System Requirements The HBA requires the operating system (OS) levels, at minimum, listed in TABLE 1-2 Supported Operating System Versions TABLE 1-2 Operating System Supported Versions (minimum) Solaris 10 OS for Solaris 10 8/07 (s10u4), 11/06 (s10u3), 6/06 (s10u2), and 1/06 (s10u1) the x64 and x86 and latest patches 119131 and 120223...
  • Page 10: Host Platform Support

    Host Platform Support The HBA is supported by the platforms and operating systems (OSs) listed in TABLE 1-3 Platform and Operating System Support TABLE 1-3 Platform Supported OS Netra™ ACTA 3060 and 3220 Solaris, Linux servers TABLE 1-2 * See for specific OS versions.
  • Page 11: Software Support

    10 Gb Brocade M6140 Director ■ 10 Gb Brocade Mi10K Director ■ 2 Gb McDATA Sphereon 4300 switch ■ 2 Gb McDATA Sphereon 4500 switch ■ 2 Gb McDATA Intrepid 6064 Director ■ 4 Gb McDATA Sphereon 4400 and 4700 switches ■...
  • Page 12 Sun StorageTek ATCA 4Gb FC Dual Port HBA Installation Guide • April 2010...
  • Page 13: Hardware Installation And Removal

    C H A P T E R Hardware Installation and Removal This chapter describes the tasks required to install and remove the HBA. Refer to your system installation or service manual for detailed instructions. This chapter contains the following topics: “Observing ESD and Handling Precautions”...
  • Page 14: Installing The Hardware

    Place the HBA on a properly grounded antistatic work surface pad when it is out ■ of its protective antistatic bag. Installing the Hardware The hardware installation process involves the following general steps: “To Verify the PPS Shelf Manager Firmware Version” on page 8 ■...
  • Page 15 Removing the AMC Slot Filler Panel FIGURE 2-1 Note – A module handle is at the bottom of the HBA. When you install the HBA, the position of the module handle (pulled out or pushed in) does not matter. nsert the HBA through the cutout and into the AMC slot ( FIGURE 2-2 Chapter 2 Hardware Installation and Removal...
  • Page 16: To Connect The Optical Cable

    Inserting the HBA Into the AMC Connector FIGURE 2-2 4. Carefully plug the HBA into the AMC connector ( FIGURE 2-2 Ensure that the HBA is seated correctly in the connector. Caution – Do not use excessive force when installing the HBA into the slot. You might damage the AMC connector on the Netra board, causing permanent damage to the HBA or board.
  • Page 17 Optical Cable Specifications TABLE 2-1 Fiber-Optic Cable Maximum Length Minimum Length Connector µ 62.5/125 300 meters at 1.0625 Gbps 2 meters (multimode) 150 meters at 2.125 Gbps 70 meters at 4.25 Gbps µ 50/125 500 meters at 1.0625 Gbps 2 meters (multimode) 300 meters at 2.125 Gbps 150 meters at 4.25 Gbps...
  • Page 18 3. Observe the port LEDs status for the power-on self test (POST) results as shown in TABLE 2-2 summarizes port LED indicator combinations. Refer to TABLE 2-2 FIGURE 2-4 determine the location of the LEDs. Each port has a corresponding set of LEDs that provide a visual indication of the operating state.
  • Page 19: To Verify The Installation (Solaris Os)

    LEDs FIGURE 2-4 ▼ To Verify the Installation (Solaris OS) 1. Use the command to verify proper HBA installation. cfgadm cfgadm Ap_Id Type Receptacle Occupant Condition connected configured connected configured pcie5 fibre/hp connected configured If the HBA is properly installed and connected, you will see output similar to that shown in the example.
  • Page 20: To Verify Attached Storage (Solaris Os)

    ▼ To Verify Attached Storage (Solaris OS) 1. Use the cfgadm -al command to verify attached storage. cfgadm -al Ap_Id Type Receptacle Occupant Condition fc-fabric connected configured unknown c3::200600a0b816005e disk connected configured unknown c3::200700a0b816005e disk connected configured unknown connected unconfigured unknown pcie5 fibre/hp connected...
  • Page 21: Removing The Hardware

    Removing the Hardware The following instructions describe the tasks required to remove the HBA. Refer to your system installation or service manual for detailed HBA adapter removal instructions. The hardware removal process involves following these general steps: 1. Preparing the HBA for hot-plug removal with one of the following: The module handle ■...
  • Page 22: To Remove The Hba Hardware

    3. Use the cfgadm -c disconnect command to prepare the HBA for removal. A flashing Power indicator LED indicates that the HBA is being prepared for removal. A dark Power indicator LED indicates that the HBA is ready to be removed.
  • Page 23: Hba Software Installation

    C H A P T E R HBA Software Installation This chapter describes the Solaris driver software that is required to support the HBA. The chapter contains the following section: “Installing Software for the Solaris OS” on page 17 ■ “Installing Software for the Wind River Linux OS”...
  • Page 24: Solaris Diagnostic Support

    Solaris Diagnostic Support Diagnostic support for the HBA is included in Oracle’s SunVTS software beginning with version 6.3. SunVTS is included with the Solaris 10 11/06 (s10u3) release and is also available for download at: http://www.sun.com/oem/products/vts The emlxtest utility, provided as part of the SunVTS software, supports the following functions: Connectivity verification ■...
  • Page 25: Installing Software For The Red Hat Enterprise Linux Os

    Note – When you contact Wind River customer support, be sure to specify all components in your hardware environment (including this HBA). This will ensure you receive all software that is required to run in the hardware environment. Installing Software for the Red Hat Enterprise Linux OS No updates are required to support the HBA on minimum supported versions of the Red Hat Enterprise Linux OS.
  • Page 26 Sun StorageTek ATCA 4Gb FC Dual Port HBA Installation Guide • April 2010...
  • Page 27: Known Issues

    C H A P T E R Known Issues This chapter contains any known issues with the HBA. The chapter contains the following topic: “Potential AMC I/O Card Corruption” on page 21 ■ Potential AMC I/O Card Corruption Issue: If you are using Oracle’s Sun Netra CT900 ATCA Blade Server or are using any Pigeon Point Systems Shelf Manager, the Shelf Manager will corrupt any AMC I/O cards when the Shelf Manager firmware is not at the latest version.
  • Page 28 ● If you have a non-Oracle ATCA chassis, contact Pigeon Point Systems customer support for information about downloading the latest firmware version: http://www.pigeonpoint.com/contact.html You can also contact Pigeon Point Systems customer support at: support@pigeonpoint.com Sun StorageTek ATCA 4Gb FC Dual Port HBA Installation Guide • April 2010...
  • Page 29: Declaration Of Conformity, Safety, And Regulatory Statements

    A P P E N D I X Declaration of Conformity, Safety, and Regulatory Statements This appendix provides Declaration of Conformity, safety, and regulatory statements for the HBA. The appendix contains the following topics: “Declaration of Conformity” on page 25 ■...
  • Page 30 Sun StorageTek ATCA 4Gb FC Dual Port HBA Installation Guide • April 2010...
  • Page 31: Declaration Of Conformity

    Declaration of Conformity To receive a copy of the latest Declaration of Conformity (DoC) for the product, either contact your local Oracle sales representative, or create an online request at: https://www2.sun.de/dct/forms/reg_us_1607_755_0.jsp...
  • Page 32 Sun StorageTek ATCA 4Gb FC Dual Port HBA Installation Guide • April 2010...
  • Page 33: Safety Agency Compliance Statements

    Safety Agency Compliance Depending on the type of power switch your device has, one of the following symbols may be used: Statements On – Applies AC power to the system. Read this section before beginning any procedure. The following text provides safety precautions to follow when installing an Oracle product.
  • Page 34 The following caution applies only to devices with a Caution – Not all power cords have the same Standby power switch: current ratings. Do not use the power cord provided with your equipment for any other Caution – The power switch of this product products or use.
  • Page 35 Energy Storage Module Caution might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing Caution – There is a danger of shock or this concern. equipment damage if energy storage modules –...
  • Page 36 Laser Compliance Notice Ce produit est destiné à être utilisé dans des zones à ■ accès limité, dans lesquelles les accès sont contrôlés Sun products that use laser technology comply with Class 1 au moyen de systèmes de sécurité (par exemple, à clé, laser requirements.
  • Page 37 Positionnement d’un produit Sun système. Assurez-vous de le brancher dans une prise d'alimentation mise à la terre près du système et facile d'accès. Ne le branchez Attention – Evitez d'obstruer ou de recouvrir pas lorsque l'alimentation électrique ne se les orifices de votre produit Sun. N'installez trouve pas dans le châssis du système.
  • Page 38 endommager ou de vous exposer à un choc conséquences d'une éventuelle surcharge des circuits sur la protection de surintensité et sur le câblage électrique. Remplacez les modules de stockage d'alimentation. En l'occurrence, les valeurs nominales d’énergie uniquement par les modules de de la plaque signalétique du matériel doivent être remplacement que Sun Microsystems fournit, prises en compte.
  • Page 39 Stellen Sie sicher, dass Spannung und Frequenz der ■ Stromversorgung den Nennleistungen auf dem am Attention – Afin d'empêcher des Gerät angebrachten Etikett entsprechen. températures de fonctionnement extrêmes provoquées par une aération insuffisante, Führen Sie niemals Fremdobjekte in die Öffnungen ■...
  • Page 40 Modifikationen des Geräts Achtung – Beim Netzschalter dieses Geräts Nehmen Sie keine elektrischen oder mechanischen handelt es sich nur um einen Ein/Standby- Gerätemodifikationen vor. Sun Microsystems ist für die Schalter. Zum völligen Abtrennen des Systems Einhaltung der Sicherheitsvorschriften von modifizierten von der Stromversorgung dient hauptsächlich Sun-Produkten nicht haftbar.
  • Page 41 Sicherheitshinweise zum - Die Montage des Geräts im ■ Mechanische Belastung Rack sollte so erfolgen, dass bei einer Energiespeichermodul ungleichmäßigen mechanischen Belastung keine gefährliche Betriebsbedingung entstehen kann. Achtung – Bei unsachgemäßer Handhabung - Der Anschluss des Geräts an ■ Stromkreisüberlastung oder unsachgemäßem Austausch von den Speisestromkreis und die Wirkung, die ein Energiespeichermodulen besteht die Gefahr...
  • Page 42 Warnungen bezüglich in Racks eingebauter CD- und DVD-Geräte Systeme Die folgende Warnung gilt für CD-, DVD- und andere optische Geräte: Die folgenden Warnungen gelten für Racks und in Racks eingebaute Systeme: Achtung – Die hier nicht aufgeführte Verwendung von Steuerelementen, Achtung –...
  • Page 43 Conexión del cable de alimentación Precaución – Superficie caliente. Evite todo contacto. Las superficies están calientes y Precaución – Los productos Sun se han pueden causar lesiones personales si se tocan. diseñado para funcionar con sistemas de alimentación que cuenten con un conductor neutro a tierra (con conexión a tierra de Precaución –...
  • Page 44 servicio del producto. No desmonte módulos Precaución – En los productos que cuentan ni intente recargarlos fuera del sistema. No con varios cables de alimentación, debe elimine los módulos. En su lugar, devuélvalos desconectar todos los cables de alimentación a Sun Microsystems de conformidad con los para cortar por completo la alimentación procedimientos de Sun para el producto.
  • Page 45 la utilización de láser Precaución – Los equipos instalados por Los productos Sun que utilizan tecnología láser cumplen los deslizamiento o sobre raíles no deben requisitos establecidos para los productos láser de clase 1. utilizarse como estantería o espacio de trabajo. Advertencia sobre el sistema en bastidor Dispositivos de CD y DVD Las advertencias siguientes se aplican a los sistemas...
  • Page 46 Danmark Norge Advarsel! – Litiumbatteri — Eksplosionsfare Advarsel – Apparatet må tilkoples jordet ved fejlagtig håndtering. Udskiftning må kun stikkontakt. ske med batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren. Sverige Varning – Apparaten skall anslutas till jordat Suomi uttag.
  • Page 47: Regulatory Compliance Statements

    Regulatory Compliance Statements Your Sun product is marked to indicate its compliance class: • Federal Communications Commission (FCC) — USA • Industry Canada Equipment Standard for Digital Equipment (ICES-003) — Canada • Bureau of Standards Metrology and Inspection (BSMI) — Taiwan Please read the appropriate section that corresponds to the marking on your Sun product before attempting to install the product.
  • Page 48 BSMI Class A Notice The following statement is applicable to products shipped to Taiwan and marked as Class A on the product compliance label. D33728 Korean MIC Class A Statement Sun StorageTek ATCA 4Gb FC Dual Port HBA Installation Guide • April 2010...

Table of Contents