GE Profile DPGT750 Owner's Manual And Installation Instructions page 30

Table of Contents

Advertisement

Installation
Instructions
EXHAUSTING
THE DRYER (cont.)
WARNING
The correct exhaust
installation
is your
responsibility.
USE ONLY METAL 4" DUCT. DO NOT USE
DUCT LONGER
THAN
SPECIFIED
IN THE
EXHAUST
LENGTH
TABLE.
Ducting
longer
than
150 equivalent
feet will:
• Increase
the drying
times
and the energy
cost.
• Reduce the dryer
life.
• Accumulate
lint, creating
a potential
fire
hazard.
EXAMPLE
ONLY
The following
chart describes
an example
of
one possible
ductwork
installation.
Problems
due to incorrect
installation
are not
covered
by the warranty.
The length
of the exhaust
system
depends
upon the type
of duct,
number
of turns
and
the type
of exhaust
hood
(wall
cap), and all
conditions
noted
below.
Both rigid
and flexible
metal
ducts
are shown
in the table.
For satisfactory
air movement,
the total
duct
length
should
not exceed
150 equivalent
feet.
-J
_o_
ii°
t r"
w
>-
a
v
Z
n
m_
£-4,
SO
EQUIVALENT
RIGID
NUMBER
DUCT PIECES
LENGTH
X
USED
1 Ft.
X
(4)
Rigid
Metal
Ducting
(Preferred)
Elbows
(90°/45 o)
Turns
Less
Than
4 Ft.
10 Ft.
X
(3)
2 Ft.
X
(1)
_
Rigid
Ducting
1 Ft.
X
(5)
_
_
4" Wall Cap
5Ft.
X
(1)
I,,°;4-
Total
Ductwork
Length
TOTAL
MUST
BE LESS THAN
OR EQUAL
TO 150 FT.
EQUIVALENT
=
LENGTH
=
4 Ft.
=
30 Ft.
=
2 Ft.
=
5 Ft.
=
5 Ft.
=
46 Ft.
3O

Advertisement

Table of Contents
loading

Table of Contents