Installation
Instructions
CONNECTING
A GAS DRYER (cont.)
GAS REQUIREMENTS
Zi,WARNING
• Installation
must
conform
to local codes
and ordinances,
or in their
absence,
the
NATIONAL
FUEL GAS CODE, ANSI Z223.
• This gas dryer
is equipped
with
a Valve
and
Burner
Assembly
for use only
with
natural
gas. Using
conversion
kit WE25X10014,
your
local
service
organization
can convert
this dryer
for use with
propane
(LP) gas.
ALL CONVERSIONS
MUST
BE MADE
BY PROPERLY
TRAINED
AND QUALIFIED
PERSONNEL
AND IN ACCORDANCE
WITH
LOCAL
CODES AND
ORDINANCE
REQUIREMENTS.
• The dryer
must
be disconnected
from
the gas supply
piping
system
during
any
pressure
testing
of that system
at a test
pressure
in excess
of 0.5 PSI (3.4 KPa).
• The dryer
must
be isolated
from
the
gas supply
piping
system
by closing
the
equipment
shut-off
valve
during
any
pressure
testing
of the gas supply
piping
of test pressure
equal to or less than
0.5 PSI (3.4KPa).
DRYER GAS SUPPLY CONNECTION
,
//
_
_
4
3V4
\\
_
J
(8.2 cm) I [_[_
(J
I
2_
_ (6 ca_m_ 3/8" NPT MALE THREAD GASa_UPPLY
NOTE: Add to vertical
dimension
the distance
between
cabinet
bottom
to floor,
GAS SUPPLY
• A 1/8" National
Pipe Taper thread
plugged
tapping,
accessible
for test gauge
connection,
must
be installed
immediately
upstream
of the gas supply
connection
to
the dryer.
Contact
your
local
gas utility
should
you
have questions
on the
installation
of the plugged
tapping.
• Supply
line is to be 1/2" rigid
pipe and
equipped
with
an accessible
shutoff
within
6 feet of, and in the same
room
with,
the
dryer.
• Use pipe compound
appropriate
for natural
or LP gas or use Teflon ® tape.
• Connect
flexible
metal
connector
to dryer
and gas supply.
CONNECTING
THE DRYER TO THE
GAS SUPPLY
[]
Install
a female
3/8" NPT elbow
at the end
of the dryer
gas inlet.
Install
a 3/8" flare
union
adapter
to the
female
elbow.
IMPORTANT:
Use a pipe wrench
to
securely
hold
on to the end of the dryer
gas inlet to prevent
twisting
the inlet.
NOTE: Apply
pipe compound
or Teflon ®
tape to the threads
of the adapter
and
dryer
gas inlet.
Dryer Gas Inlet
Apply