Electrical Connections
Motor Specifications
The AC motor
used in this saw is a capacitor-
start, non-reversible
type having the following
specifications:
19711
19715
Rated H.R
................
1.5
1.5
Maximum
Developed
H.R
..
2.5
2.75
Voltage
...................
120 120/240
Amperes
..................
11.0
12/6
Hertz (cycles) ..............
60
60
Phase
....................
Single
Single
RPM .....................
3450
3450
Rotation
of Arbor
Shaft
....
Clock-
Clock-
wise
wise
Power
Supply
t'x
_IL WARNING:
Your saw is wired at
the factory
for 120V operation.
Connect
to a 120V, 15-AMP,
branch
circuit and
use a 15-AMP,
time delay fuse
or circuit
breaker.
Failure to connect
in this way
can result in injury from
shock or fire.
A'k
4Ilk WARNING:
To avoid shock or fire, if
power cord is worn, cut, or damaged
in
any way have it replaced
immediately.
Your
unit is wired
for 120V and it has a plug
that
looks
like the one shown
below.
(Figure
83)
3-Prong Plug
Grounding
Prong
Properly
Grounded
Outlet
Fig 83 - Plug for Less Than 150V
Your saw must be properly
grounded.
Not all
outlets
are properly
grounded.
If you are not
sure that your outlet
is properly
grounded,
have it checked
by a qualified
electrician.
_lb WARNING:
If not properly
grounded
this power
tool can cause
electrical
shock,
particularly
when
used
in damp
locations.
ik
_
41LWARNINL_:
If an electrical
shock
oc-
curs, your reaction
to the shock may
bring
your hands into contact with the
blade.
This
power
tool
is equipped
with
a 3-
conductor
cord
and grounding
type
plug listed
by Underwriters'
I,aboratories.
The ground
conductor
has a green
jacket
and
is attached
to the tool
housing
at one end and
to the
ground
prong
in the attachment
plug
at the
other
end.
This plug requires
a mating
3-conductor
grounded
type outlet
as shown above.
If you
have an outlet
that is of the two prong type, it
is recommended
that you have a qualified
electrician
replace
the it with a properly
grounded
three
prong outlet.
34