Inspect tool cords periodically and if damaged, have them
repaired by an authorized service facility.
Green (or green and yellow) conductor in cord is the
grounding wire. If repair or replacement of the electric cord
or plug is necessary, do not connect the green (or green
and yellow) wire to a live terminal.
Where a 2-prong wall receptacle is encountered, it must be
replaced with a properly grounded 3-prong receptacle
installed in accordance with National Electric Code and
local codes and ordinances.
WARNING:
This work should be performed by a qualified
electrician.
A temporary 3-prong to 2-prong grounding adapter (see
Figure 41) is available for connecting plugs to a two pole out-
let if it is properly grounded.
Grounding
Make Sure
This Is
Ad_
Connected To
3-Prong Plug
A Known
Ground
2-Prong Receptacle
Figure 41 - 2-Prong Receptacle with Adapter
Do not use a 3-prong to 2-prong grounding adapter unless
permitted by local and national codes and ordinances.
(A 3-prong to 2-prong grounding adapter is not permitted
in Canada.) Where permitted, the rigid green tab or termi-
nal on the side of the adapter must be securely connected
to a permanent electrical ground such as a properly
grounded water pipe, a properly grounded outlet box or a
properly grounded wire system.
Many cover plate screws, water pipes and outlet boxes are
not properly grounded. To ensure proper ground, grounding
means must be tested by a qualified electrician.
EXTENSION
CORDS
The use of any extension cord will cause some drop in
voltage and loss of power.
°
Wires of the extension cord must be of sufficient size to
carry the current and maintain adequate voltage.
Use the table to determine the minimum wire size (A.W.G.)
extension cord.
Use only 3-wire extension cords having 3-prong grounding
type plugs and 3-pole receptacles which accept the tool plug.
°
tf the extension cord is worn, cut, or damaged in any way,
replace it immediately.
Extension Cord Length (120V Operation)
:.
Wire Size A.W.G.
Up to 25 ft .......................................
14
Up to 50 ft.......................................
12
NOTE: Using extension cords over 50 ft. long is not
recommended.
Extension Cord Length (240V Operation)
Wire Size A.W.G.
Up to 50 ft .......................................
18
50 to 100 ft.......................................
16
100 to 200 ft......................................
14
200 to 300 ft......................................
I2
NOTE: Using extension cords over 300 ft. long is not
recommended.
ELECTRICAL CONNECTIONS
WARNING: Make sure unit is off and disconnected from
powersource beforeinspecting any wiring.
The saw isprewiredfor use on a 120 volt,60HZ powersupply.
The power linesare inserteddirectlyontothe switch. The
green groundlinemustremainsecurely fastened to the frame
to properlyprotect againstelectrical shock.
240 VOLT OPERATION
• To use the saw with a 240V, single-phase
power supply,
have a qualified electrician attach a 240 volt, 15A 3-prong
plug onto saw line cord and install the proper connectors
and receptacles to power supply.
See wiring diagram (Figure 42) for wiring instructions.
(
3
)
(
2
)
1
1
(
1
)
(
4
)
1
;
L1
120V
L2
(_
3
2
_)
(
1
)
(
4
)
L1
240V
1.2
Figure 42 -Wiring
Schematic
Refer to Figures 43-52, pages 15-18.
DESCRIPTION
The Craftsman 10" Model Number 218331 contractor saw
offers precise cutting performance for all woods up to 31,_"
thick. The saw is designed for the professional user and is
ruggedly constructed for continuous service. The 10" Saw is
recommended
for use with a 10" blade.
The saw features an extra large cast iron table. Saw body has
on board storage for push stick, miter gauge, rip fence and
saw blades. Saw is equipped with a riving knife and a clear
acrylic blade guard with anti-kickback feature. Cabinet is con-
structed of heavy gauge welded steel, totally enclosed and is
ported for a 4" vacuum hose.
Rip Fence Assembly features a heavy-duty precision rip fence
that is designed for simple and one-hand maneuverability.
Front rail is calibrated in inches and millimeters with a magni-
fied window for close tolerances.
SPECIFICATIONS
Capacity
with 10" Blade:
Depth of cut at 90 °. ..............................
3%"
Maximum tilt angle of arbor (left) ....................
45 °
Depth of cut at 45 ° . .............................
23/_"
Max. cut right of blade with rip fence .................
30"
Max. cut left of blade with rip fence ..................
13"
14