Display 70 - Temporary counters of DSP
++++++++++++++
+ aaaa bbbb
+ cccc dddd
+ eeee ffff
+ gggg hhhh
++++++++++++++
aaaa
Contents of API memory location r_dsp2ftd+0 in hex format
bbbb
Contents of API memory location r_dsp2ftd+1 in hex format
cccc
Contents of API memory location r_dsp2ftd+2 in hex format
dddd
Contents of API memory location r_dsp2ftd+3 in hex format
eeee
Contents of API memory location r_dsp2ftd+4 in hex format
ffff
Contents of API memory location r_dsp2ftd+5 in hex format
gggg
Contents of API memory location r_dsp2ftd+6 in hex format
hhhh
Contents of API memory location r_dsp2ftd+7 in hex format
The display is to be used by special debugging DSP SW which can put some useful information
to the memory locations on API RAM. When this display is selected then MCU copies the
contents of those memory locations into display with format specified above.
This display may not be included in normal SW releases.
Display 71 & 72 - Control DSP audio enhancements 1 & 2
**************
*AUDIO
*ENHANCEMENT *
*DISPLAY 1/2 *
*
XXXXX
**************
Caution : playing around with this display may result in (temporary) malfunction of the
audio path in your phone. Please be careful.
XXXXX
Control word for DSP Audio Enhancements in decimal format.
The control word is sent to the DSP in mdi audio configure message.
Prior using this display the control word must be written to location 31/32 of SIM -card in
decimal format.
When the display 71/72 is choosen from the menu, (EXECUTE MODE) the control word is sent to
the DSP in mdi audio configure message immediately. Mdi audio configure message is also sent
every time when this display is entered using arrow keys and previous display was 72/71.
Used together with display 72/71, this display makes rapid on/off switching of audio DSP
algorithms possible. Switching with arrow keys is possible only after this display or
display 72/71 has been selected from the menu. This prevents accidental on/off switching of
algorithms when browsing displays by arrow keys. Entered values are not saved to EEPROM.
Display 73 - Generic display for DSP Audio Enhancements
++++++++++++++
+ aaa bb
+cccc bb cccc+
+cccc bb cccc+
+ cccc cccc
++++++++++++++
aaa
General dB value, e.g. signal level in dB.decimal point and sign is not shown,
ie. -10.5 is show 105.
bb
General byte value, used for combined flags. Value is in hex format.
cccc
General hex value.
The display is reset and restarted when call is taken (if FT display counters are enabled).
When call is terminated the display is frozen to show last values. Display values will not
be saved to the EEPROM.
##############
+
# Temporary
+
#DSP counters#
+
#(R DSP2FTD) #
+
#
##############
##############
*
#Use menu to #
#control DSP #
#
audio
*
#enhancements#
##############
Example:
aaa+
+
#
#
#
++++++++++++++
+ 101 00
408+
+BCDE 88 7FFF+
+0001 FF 0003+
+
DEAD DEFA +
++++++++++++++
22
##############
#DB1
B1
DB2#
#HEX1 B2 HEX2#
#HEX3 B3 HEX4#
#
HEX5 HEX6 #
##############