Display 62 – Neighbour measurement counter display
++++++++++++++
+ PSW
:aaaa +
+ SYNCR:bbbb +
+ BCCH :cccc +
+ BCCHE:dddd +
++++++++++++++
aaaa
counter for neighbour PSW measurement attempts
bbbb
counter for neighbour synchronization measurement attempts
cccc
counter for neighbour BCCH measurement attempts
dddd
counter for neighbour BCCH Ext measurement attempts
Counter values are shown in hexadecimal form.
On poweroff the values of the counter displays are stored onto the EEPROM, where they will
be read during power on. To initialize the counters to zero, select display 60. Counters are
automatically reset to zero when
Display 63 – Call attempts counters
++++++++++++++
+
aa
bb
+
ccc
ddd +
+
eee
fff +
+
++++++++++++++
aa
Reason of last call release
Cause from messages DISC and REL_COMP. Refer to TS GSM 04.08/10.5.4.11/Table
10.86 for further explanation.
bb
Direction of last call release
UN : Unknown
MO : Mobile originated
MT : Mobile terminated
IN : Internal (ME CS sw)
ccc
count of all MO call attempts made
ddd
count of succeeded MO calls
eee
count of all call setups received
fff
count of succeeded MT calls
On poweroff the values of the counter displays are stored onto the EEPROM, where they will
be read during power on. To initialize the counters to zero, select display 60. Counters are
automatically reset to zero when they exceed their maximum value.
Display 64 – Location Update attempts counters
++++++++++++++
+ aa bbb ccc +
+ dd eee fff +
+
+
++++++++++++++
aa
Reason of last normal location update failure
bbb
count of normal location update attempts
ccc
count of succeeded normal location updates
dd
Reason of last periodic or IMSI attach location update failure
eee
count of all periodic and IMSI attach location update attempts
fff
count of succeeded periodic and IMSI attach location updates
On poweroff the values of the counter displays are stored onto the EEPROM, where they will
be read during power on. To initialize the counters to zero, select display 60.
Counters are automatically reset to zero when
##############
#NeghbrPSWCtr#
#SyncMeasCntr#
#BCCHMeasAtmp#
#BCCHExtMeAtm#
##############
they exceed their maximum value.
##############
+
#CalRel RelDi#
#MOCAtmp MOOK#
#AllMT
+
#
##############
##############
#Nfai NL NLOK#
#PFai PL PLOK#
+
# Loc update #
+
#
counters
##############
MTOK#
#
#
they exceed their maximum value.