Configuring Supported Devices
Setup
switchCfgSpeed. To set the speed level for a single port, use the
portCfgSpeed.
Depending on your environment you may need to force a port to use a
specific speed level. Auto negotiation may not be supported by the device.
Check the configuration information for your network components for
specific requirements. See the Fabric OS Reference Manual for a detailed
command description.
HP Surestore Director FC-64 Switch
The FC Entry Switch 8B or FC Switch 8B switch can be used with the HP
Surestore Director FC-64 switch. Specific configurations must be set on
both devices to make this work.
On the FC Entry Switch 8B or FC Switch 8B, log on to the switch with
administrative privileges and enter the following telnet commands:
1. switchDisable
2. interopMode 1
3. switchEnable
On the Director FC-64 switch, the following steps must be completed to
configure the switch for interoperability:
Step 1: Verify Unique Domain IDs
Step 2: Select a Single Surestore FC-64 Director as Principal Switch
Step 3: Verify Unique Zone Names
Step 4: Verify Brocade Product Zoning Configurations
Step 5: Verify Zone Naming Conventions
Step 6: Verify Operating Mode
Step 7: Verify Surestore FC-64 Director Switches' Operating
Parameters
Step 8: Verify Firmware Version
Step 9: Verify EFC Manager Version
Step 10: Verify Private Loop Targets on Brocade Products are
Translated to Fabric
Step 11: Add Switches to Fabric
31
Need help?
Do you have a question about the StorageWorks 8B - FC Entry Switch and is the answer not in the manual?