Environmental requirements
Printer
Audible noise
Optional peripheral cabinet
Optional bypass transport
Agency certification
XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS INSTALLATION PLANNING GUIDE
Table 3-6.
DocuPrint 96/DocuPrint 96MX Environmental and
electrical requirements (continued)
U.S. and Canada,
120/240 VAC or
60Hz:
120/208 VAC;
50 amp service;
NEMA 14-50R
KVA 7.3 (operating)
International, 50 Hz
380, 400, 415 VAC
(WYE):
(3 phase, 5 wire);
20 amp service (WYE)
International, 50 Hz
220, 230, 240 VAC (3 phase, 4 wire);
(DELTA):
30 amp service (DELTA)
Standby:
Continuous: 52 dB (A)
Impulse: N/A
Operating:
Continuous: 67dB (A)
Impulse: 72dB (A)
U.S. and Canada,
208/240 VAC (1 phase) or
60Hz:
208/220 VAC (Line 1 to line 2);
15 amp service;
NEMA6-15R or
ANSI C73, 20R
KVA .9 in both standby and operating
International, 50 Hz:
200/230 VAC (1 phase);
15 amp service
The power requirements for the bypass transport module are all
satisfied by the DocuPrint 96/DocuPrint 96MX LPS printer module.
UL, CSA, CE Mark, EC 950, VDE 0871 (Level AQ) and 0875, EEC