Status Code Value
Meaning
How to Correct
Several states can cause this message:
Case 1: The operation cannot be
performed because an association exists
a related object, or the object is in a
progress state.
Derived unit create: Case 2: The
supplied virtual disk handle is already
an attribute of another derived unit. This
may indicate a programming error
Derived unit discard: Case 3: One or
more LUNs are presented to EVA hosts
that are based on this virtual disk.
Case 4: Logical disk clear data lost: The
virtual disk is in the non-mirrored delay
window.
Case 5: LDAD discard: The operation
cannot be performed because one or
more virtual disks still exist, the disk
group still may be recovering its
capacity, or this is the last disk group
that exists.
Case 6: LDAD resolve condition: The
disk group contains a disk volume that
is in a data-lost state. This condition
cannot be resolved.
Case 7: Physical Store erase volume:
The disk is a part of a disk group and
cannot be erased.
Case 8: Storage cell discard: The
storage cell contains one or more virtual
disks or LUN presentations.
Case 9: Storage cell client discard: =
The EVA host contains one or more LUN
presentations.
Case 10: SCVD discard: The virtual disk
contains one or more derived units and
cannot be discarded. This may indicate
a programming error.
Case 11: SCVD set capacity: The
capacity cannot be modified because
the virtual disk has a dependency on
either a snapshot or snapclone.
Case 12: SCVD set disk cache policy:
The virtual disk cache policy cannot be
modified while the virtual disk is
presented and enabled.
Case 13: SCVD set logical disk: The
logical disk attribute is already set, or
the supplied logical disk is already a
member of another virtual disk.
Case 14: VOLUME set requested usage:
The disk volume is already a member of
a disk group or is in the state of being
removed from a disk group.
HP StorageWorks 6400/8400 Enterprise Virtual Array user guide