Vmware - HP StorageWorks 6400/8400 - Enterprise Virtual Array User Manual

Enterprise virtual array
Hide thumbs Also See for StorageWorks 6400/8400 - Enterprise Virtual Array:
Table of Contents

Advertisement

VMware

Table 34 VMware failure scenarios.
Fault stimulus
Server failure (host power-cycled)
Switch failure (SAN switch disabled)
Controller failure
Controller restart
Server path failure
Storage path failure
128
Single Path Implementation
Failure effect
OS reboots, automatically checks disks. HSV disks must be manually
checked unless auto mounted by the system.
Short: I/O suspended, possible data loss.
Long: I/O halts with I/O errors, data loss. HBA driver must be
reloaded before failed drives can be recovered, fsck should be run
on any failed drives before remounting.
Short term: I/O suspended, possible data loss.
Long term: I/O halts with I/O errors, data loss. Cannot reload
driver, need to reboot system, fsck should be run on any failed disks
before remounting.
Short term: I/O suspended, possible data loss.
Long term: I/O halts with I/O errors, data loss. Cannot reload
driver, need to reboot system, fsck should be run on any failed disks
before remounting.
Short: I/O suspended, possible data loss.
Long: I/O halts with I/O errors, data loss. HBA driver must be
reloaded before failed drives can be recovered, fsck should be run
on any failed drives before remounting.
Short: I/O suspended, possible data loss.
Long: I/O halts with I/O errors, data loss. HBA driver must be
reloaded before failed drives can be recovered, fsck should be run
on any failed drives before remounting.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks 6400Storageworks 8400

Table of Contents