The SMM Modem Dialing area of the dialog contains settings for the PC Card modem in
the ISM board. The Console Configuration area of the dialog contains settings to deliver
out-band alerts.
4.
Select the appropriate baud rate in the Baud box. The baud rate is the rate of
communication between the ISM board and the modem. A higher baud rate than the
modem baud rate is needed to account for overhead; for example, choose 19200 for a
14.4 KB per second modem.
5.
Select the correct method of parity checking in the Parity box. The possible values are
None, Odd, or Even.
6.
Select the method to use for dialing in the Dialing box. The possible values are Tone or
Pulse. If you have touch-tone phone service, select Tone; otherwise, select Pulse.
7.
Select the number of stop bits in the Stop Bits box. The possible values are 1, 1.5, or 2.
8.
Select the number of data bits in the Data Bits box. The possible values are 7 or 8.
9.
Select the data flow control setting in the Flow Control box. The possible values are
None (software) or RTS/CTS (hardware).
NOTE
The Flow Control value must be the same as the Flow Control setting in the Communications
Setting dialog (used for storing modem information).
10. Type the full telephone number the modem will use to contact the monitoring console in
the Phone Number box. You must type a number in the box for the modem to receive
out-band alerts.
11. Type a modem string in the Dialing Modem String box (for example, ATM0). The
modem string is sent to the modem just before dialing the phone number in the Phone
Number box. Unless your modem has special initialization requirements, use ATM0 as
the modem string.
NOTE
Do not use ATDT or ATDP as the modem string.
12. Type the range of days the modem can be used in the Day Range boxes. The values for
days range from 0 to 6, with 0 = Sunday and 6 = Saturday.
13. Type the time the modem can be used in the Time Range boxes. The times are in 24-hour
format. For example, specifying a time range of 08:00 to 23:30 would be the hours of
8:00 a.m. through 11:30 p.m.
14. Click OK to close the Configure Modem dialog.
15. Select Autoanswer on the Configure Modem Settings dialog to configure the PC Card
modem in the ISM board. The Edit Autoanswer Settings dialog displays.