Maintenance Instruction; Ducting - Windster WS-5530SS Operation Manual

Hide thumbs Also See for WS-5530SS:
Table of Contents

Advertisement

L. Maintenance Instruction
L. MAINTENANCE INSTRUCTION
1. Maintenance shall be important than repair. Please take care of the
needed maintenance in order to secure and extend the excellent
functions and using life.
Note: Before repairing the range hood. Disconnect the power source.
2. After using the machine, wipes the machine by neutral detergent in
order to keep it clean and maintain the appearance with brightness
and sanitation.
3. When the level of dirty oil of the collector reached 4/5 of height, it has to
be removed in order to avoid overflowing and pollution.
M. DUCTING
M. Ducting
This style of range must be vented via ducting to the outside of the house.
Follow general rules when ducting the hood: Use correct size of ducting
(6" or 7" round ), do not reduce size of ducting, make all turns gradual,
no short corners. If ducting ran will be longer than 10 feet enlarge duct by
at least 1" inch diameter after each 10 feet. Tape all joints in ducting and
all gasketed openings on hood for a tight seal.
For round ducting from the top:
For the gray plastic (included) over the circular opening on top in order to
provide a tight seal for ducting to attach to. The GRAY ring is designed to fit
either 6" or 7" ducting.